71m6543h-igtr/f Maxim Integrated Products, Inc., 71m6543h-igtr/f Datasheet - Page 12

no-image

71m6543h-igtr/f

Manufacturer Part Number
71m6543h-igtr/f
Description
Energy Meter Ic
Manufacturer
Maxim Integrated Products, Inc.
Datasheet
71M6543F/H Data Sheet
number of LCD segments and DIO pins can be implemented in software to accommodate various
requirements.
In addition to the temperature-trimmed ultra-precision voltage reference, the on-chip digital temperature
compensation mechanism includes a temperature sensor and associated controls for correction of unwanted
temperature effects on metrology and RTC accuracy (i.e., to meet the requirements of ANSI and IEC
standards). Temperature-dependent external components such as the crystal oscillator, current
transformers (CTs), Current Shunts and their corresponding signal conditioning circuits can be character-
ized and their correction factors can be programmed to produce electricity meters with exceptional accuracy
over the industrial temperature range.
One of the two internal UARTs is adapted to support an Infrared LED with internal drive and sense
configuration and can also function as a standard UART. The optical output can be modulated at 38 kHz.
This flexibility makes it possible to implement AMR meters with an IR interface. A block diagram of the IC
is shown in
2.2
The AFE functions as a data acquisition system, controlled by the MPU. The 71M6543F/H AFE may also
be augmented by isolated 71M6xx3 sensors in order to support low-cost current shunt sensors.
and
are connected directly to the 71M6543F/H (i.e., IADC0-IADC1, VADC8, VADC9 and VADC10) are
multiplexed into the single second-order sigma-delta ADC input for sampling in the 71M6543F/H. The
71M6543F/H ADC output is decimated by the FIR filter and stored in CE RAM where it can be accessed
and processed by the CE.
Shunt current sensors that are isolated by using a 71M6xx3 device, are sampled by a second-order
sigma delta ADC in the 71M6xx3 and the signal samples are transferred over the digital isolation interface
through the low-cost isolation pulse transformer.
Figure 2
Figure 2
plus three remote (isolated) shunt sensors. As seen in
connected via the 71M6xx3, the samples associated with this current channel are not routed to the
multiplexer, and are instead transferred digitally to the 71M6543F/H via the isolation interface and are
directly stored in CE RAM. The MUX_SELn[3:0] I/O RAM control fields allow the MPU to configure the
AFE for the desired multiplexer sampling sequence. Refer to
code and the corresponding AFE settings.
See
12
Figure 3
Figure 31
Analog Front-End (AFE)
shows the 71M6543F/H using shunt current sensors and the 71M6xx3 isolated sensor devices.
supports neutral current measurement with a local shunt connected to the IADC0-IADC1 input
Figure
show the two most common configurations; other configurations are possible. Sensors that
for the meter wiring configuration corresponding to
Figure 2: AFE Block Diagram (Shunts: One-Local, Three-Remotes)
1.
Remote
Remote
Remote
Shunt
Shunt
Shunt
IB
IC
IA
INN
INN
INN
INP
INP
INP
71M6xx3
71M6xx3
71M6xx3
© 2008–2011 Teridian Semiconductor Corporation
Shunt
Local
IN*
SP
SP
SP
SN
SN
SN
VADC10 (VC)
VADC8 (VA)
VADC9 (VB)
IADC3
IADC4
IADC5
IADC2
IADC6
IADC7
IADC0
IADC1
*IN = Neutral Current
Isolation
Interface
MUX
Digital
Figure
VREF
VADC
Table 1
2, when a remote isolated shunt sensor is
71M6543F/H
VREF
Figure
CONVERTER
VREF
22
22
22
and
∆Σ ADC
FIR
2.
Table 2
22
CE RAM
9/17/2010
for the appropriate CE
Figure
v1.0
2,