18.3.4.3 PWM Initialization
To ensure correct operation when generating unbuffered or buffered PWM signals, use this initialization
procedure:
Setting MS0B links channels 0 and 1 and configures them for buffered PWM operation. The TIMB
channel 0 registers (TBCH0H–TBCH0L) initially control the buffered PWM output. TIMB status control
register 0 (TBSC0) controls and monitors the PWM signal from the linked channels. MS0B takes priority
over MS0A.
Clearing the toggle-on-overflow bit, TOVx, inhibits output toggles on TIMB overflows. Subsequent output
compares try to force the output to a state it is already in and have no effect. The result is a 0% duty cycle
output.
Setting the channel x maximum duty cycle bit (CHxMAX) and setting the TOVx bit generates a 100% duty
cycle output. See
18.4 Interrupts
These TIMB sources can generate interrupt requests:
Freescale Semiconductor
1. In the TIMB status and control register (TBSC):
2. In the TIMB counter modulo registers (TBMODH–TBMODL), write the value for the required PWM
3. In the TIMB channel x registers (TBCHxH–TBCHxL), write the value for the required pulse width.
4. In TIMB channel x status and control register (TBSCx):
5. In the TIMB status control register (TBSC), clear the TIMB stop bit, TSTOP.
period.
TIMB overflow flag (TOF) — The TOF bit is set when the TIMB counter reaches the modulo value
programmed in the TIMB counter modulo registers. The TIMB overflow interrupt enable bit, TOIE,
enables TIMB overflow CPU interrupt requests. TOF and TOIE are in the TIMB status and control
register.
TIMB channel flags (CH1F–CH0F) — The CHxF bit is set when an input capture or output compare
occurs on channel x. Channel x TIMB CPU interrupt requests are controlled by the channel x
interrupt enable bit, CHxIE.
a. Stop the TIMB counter by setting the TIMB stop bit, TSTOP.
b. Reset the TIMB counter prescaler by setting the TIMB reset bit, TRST.
a. Write 0:1 (for unbuffered output compare or PWM signals) or 1:0 (for buffered output compare
b. Write 1 to the toggle-on-overflow bit, TOVx.
c. Write 1:0 (to clear output on compare) or 1:1 (to set output on compare) to the edge/level
or PWM signals) to the mode select bits, MSxB–MSxA. See
select bits, ELSxB–ELSxA. The output action on compare must force the output to the
complement of the pulse width level. See
In PWM signal generation, do not program the PWM channel to toggle on
output compare. Toggling on output compare prevents reliable 0% duty
cycle generation and removes the ability of the channel to self-correct in the
event of software error or noise. Toggling on output compare can also
cause incorrect PWM signal generation when changing the PWM pulse
width to a new, much larger value.
18.8.4 TIMB Channel Status and Control
MC68HC908EY16A • MC68HC908EY8A Data Sheet, Rev. 1
NOTE
Table
Registers.
18-2.
Table
18-2.
Interrupts
225