For example, C
C
= 20.25pF. The entire range for the series combination of
load capacitance goes from 4.5pF to 20.25pF in 0.25pF
steps. Note that these are typical values.
BATTERY MODE ATR SELECTION (BMATR <1:0>)
Since the accuracy of the crystal oscillator is dependent on
the V
to adjust the capacitance between V
device switches between power sources.
DIGITAL TRIMMING REGISTER (DTR <2:0>)
The digital trimming bits DTR0, DTR1, and DTR2 adjust the
average number of counts per second and average the ppm
error to achieve better accuracy.
• DTR2 is a sign bit. DTR2 = “0” means frequency
• DTR1 and DTR0 are both scale bits. DTR1 gives 40ppm
A range from -60ppm to +60ppm can be represented by
using these three bits (see Table 13).
Note that the DTR adjustment will affect the frequency of the
clock at F
32.768kHz. DTR can be used in conjunction with ATR and
F
Applications Section).
OUT
LOAD
compensation is >0. DTR2 = “1” means frequency
compensation is <0.
adjustment and DTR0 gives 20ppm adjustment.
DTR2
DD
BMATR1
0
0
0
0
1
1
1
1
to accurately set the oscillator frequency (see the
(ATR = 100000) = 4.5pF, and C
/V
0
0
1
1
TABLE 13. DIGITAL TRIMMING REGISTERS
OUT
BAT
DTR REGISTER
, for all frequency selections except for
operation, the ISL1219 provides the capability
LOAD
DTR1
0
0
1
1
0
0
1
1
(ATR = 00000) = 12.5pF,
BMATR0
TABLE 12.
0
1
0
1
16
DTR0
0
1
0
1
0
1
0
1
0pF
-0.5pF (≈ +2ppm)
+0.5pF (≈ -2ppm)
+1pF (≈ -4ppm)
DD
LOAD
and V
(C
CAPACITANCE
FREQUENCY PPM
BAT
(ATR = 011111)
ESTIMATED
DELTA
0 (default)
BAT
TO C
+20
+40
+60
-20
-40
-60
0
when the
VDD
)
ISL1219
Alarm Registers
Addresses [0Ch to 11h]
The alarm register bytes are set up identical to the RTC
register bytes, except that the MSB of each byte functions as
an enable bit (enable = “1”). These enable bits specify which
alarm registers (seconds, minutes, etc.) are used to make
the comparison. Note that there is no alarm byte for year.
The alarm function works as a comparison between the
alarm registers and the RTC registers. As the RTC
advances, the alarm will be triggered once a match occurs
between the alarm registers and the RTC registers. Any one
alarm register, multiple registers, or all registers can be
enabled for a match.
There are two alarm operation modes: Single Event and
periodic Interrupt Mode:
• Single Event Mode is enabled by setting the ALME bit to
• Interrupt Mode is enabled by setting the ALME bit to “1”,
To clear an alarm, the ALM bit in the status register must be
set to “0” with a write. Note that if the ARST bit is set to 1
(address 07h, bit 7), the ALM bit will automatically be cleared
when the status register is read.
“1”, the IM bit to “0”, and disabling the frequency output.
This mode permits a one-time match between the alarm
registers and the RTC registers. Once this match occurs,
the ALM bit is set to “1” and the IRQ output will be pulled
low and will remain low until the ALM bit is reset. This can
be done manually or by using the auto-reset feature.
the IM bit to “1”, and disabling the frequency output. The
IRQ output will now be pulsed each time an alarm occurs.
This means that once the interrupt mode alarm is set, it
will continue to alarm for each occurring match of the
alarm and present time. This mode is convenient for
hourly or daily hardware interrupts in microcontroller
applications such as security cameras or utility meter
reading.
August 14, 2006
FN6314.1