Datasheet

Specifications of AD9937KCPRL

Analog Front End Type
CCD
Analog Front End Category
Video
Interface Type
Serial (3-Wire)
Input Voltage Range
0.5V
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (typ)
3V
Operating Supply Voltage (max)
3.6V
Resolution
10b
Number Of Adc's
1
Power Supply Type
Analog/Digital
Operating Temp Range
-25C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
56
Package Type
LFCSP EP
Number Of Channels
1
Lead Free Status / RoHS Status
Not Compliant
AD9937
SPECIAL HORIZONTAL PATTERN TIMING
The AD9937 provides the ability to interrupt the normal hori-
zontal H1(A–D) and H2(A, B) clocking in order to apply a
special pattern on these outputs. This special horizontal pattern
timing occurs during the period when the LM outputs are active.
Table XVI lists the registers used to program the special H
patterns. Figure 28 provides an example of a special H pattern
being applied to the H1A output.
The timing diagram shown in Figure 28 identifies the registers
associated with outputting the special H patterns. Although only
HD COUNTER
LM COUNTER
LM COUNTER
HD COUNTER
12-BIT
8-BIT
LMx
12-BIT
8-BIT
LMx
1
NOTES
1
2
1
LMSTART0
x = 0, 1 (TWO UNIQUE SETS OF LM OUTPUTS CAN BE PROGRAMMED)
n = 0, 1, 2, 3, 4 (INDIVIDUAL REPETITION CONTROL FOR EACH CCD REGION)
LMSTART0
LMLENx
LMLENx
2
Figure 26. Example of LM Pulse with LMSTART1 < HDLEN
Figure 27. Example of LM Pulse with LMSTART1 > HDLEN
3
1
LM PULSE SET 1
LM PULSE SET 1
LMSTART1
LMREPn
LMREPn = 3
–32–
2
= 3
the H1A output is shown, the same special H timing can be
independently configured on the remaining horizontal outputs
by using the registers described in Table XVI. As shown in
Figure 28, the special H1A output begins when SPHSTARTx
is reached. It is important to note that there are two SPHSTART
registers. If SPHPATSEL = 0, the SPHSTART0 register will
be used, whereas if SPHPATSEL = 1, the SPHSTART1 regis-
ter will be used. The special H patterns can be enabled and
disabled for each of the five CCD regions by using the SPHENx
(x = 0, 1, 2, 3, 4).
PROGRAMMABLE CLOCK POSITIONS
1. LM_INVERT (PROGRAMMABLE AT CONTROL 0x04)
2. LMTOG1_x (PROGRAMMABLE AT HLM_REG(8))
3. LMTOG2_x (PROGRAMMABLE AT HLM_REG(8))
LM PULSE SET 2
REV. 0