3UG4622-1AW30 SIEMENS, 3UG4622-1AW30 Datasheet - Page 36

RELAY, MONITOR, 22.5MM

3UG4622-1AW30

Manufacturer Part Number
3UG4622-1AW30
Description
RELAY, MONITOR, 22.5MM
Manufacturer
SIEMENS
Series
3UG46r
Datasheet

Specifications of 3UG4622-1AW30

Contact Configuration
SPCO
Power Consumption
4VA
Supply Voltage Max
240VAC
Contact Current Max
3A
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
230V
External Depth
86mm
Coil Frequency Max
60Hz
Coil Operating Frequency Min
50Hz
3UF18 current transformers
for overload protection
Short-circuit protection with fuses for motor feeders for
short-circuit currents up to 50 kA at 690 V
1) Voltage tolerance – 5 %.
2) Assignment and short-circuit protective devices
3) Note the operational voltage.
Overload relays
3UF18 43-1BA00
3UF18 43-1AA00
3UF18 43-2BA00
3UF18 45-2CA00
3UF18 47-2DA00
3UF18 48-2EA00
Operating range 0.25 ... 2.5 A
Operating range 1.25 ... 12.5 A
Operating range 2.5 ... 25 A
Operating range 12.5 ... 50 A
Operating range 16 ... 65 A
Operating range 25 ... 100 A
7/36
acc. to IEC 60947-4-1:
Type of coordination 1:
Contactors or starters must not endanger persons or equipment in the
event of a short-circuit. They do not have to be suitable for further
operation without repair and the renewal of parts.
Type of coordination 2:
Contactors or starters must not endanger persons or equipment in the
event of a short-circuit. These must be suitable for subsequent operation.
There is a risk of contact welding.
SIMOCODE 3UF Motor Management and Control Devices
Siemens LV 1 T · 2006
Contactors Rated operational current I
3RT1 015
3RT1 015
3RT1 016
3RT1 017
3RT1 024
3RT1 025
3RT1 015
3RT1 016
3RT1 017
3RT1 024
3RT1 025
3RT1 026
3RT1 034
3RT1 035
3RT1 025
3RT1 026
3RT1 034
3RT1 035
3RT1 036
3RT1 044
3RT1 045
3RT1 046
3RT1 034
3RT1 035
3RT1 036
3RT1 044
3RT1 045
3RT1 046
3RT1 054
3RT1 044
3RT1 045
3RT1 046
3RT1 054
3RT1 055
3RT1 056
with 400 V and Class ...
5 and 10
2.5
7
9
12
12
12.5
7
9
12
12
17
25
--
--
17
25
32
40
50
--
--
--
32
40
50
65
65
--
65
65
80
95
100
--
--
1)
15
2.5
7
9
11
12
12.5
7
9
11
12
17
18
25
--
17
18
25.5
33
38.5
50
--
--
25.5
33
38.5
56
61
65
65
65
61
69
93
100
--
, 50/60 Hz
20
2.5
7
9
10
12
12.5
7
9
10
12
16
16
22.3
25
16
16
22.3
29.4
32.7
49
50
--
22.3
29.4
32.7
49
53
59
65
49
53
59
82
100
--
e
25
2.5
7
9
9.5
12
12.5
7
9
9.5
12
15
15
20.3
25
15
15
20.3
28
29.4
45
47
50
20.3
28
29.4
45
47
53
65
45
47
53
75
98
100
AC-3 in A
30
2.5
7
9
9
12
12.5
7
9
9
12
14
14
19.1
25
14
14
19.1
26.5
26.5
41.7
45
50
19.1
26.5
26.5
41.7
45
50
65
41.7
45
50
69
90
100
Type of coordination
1
Fuse links in A
LV HRC, Type 3NA
DIAZED, Type 5SB
NEOZED Type 5SE
gL/gG
25
25
25
25
35
35
25
25
25
63
63
63
63
63
63
100
100
100
100
100
100
100
125
125
160
160
160
160
160
250
250
250
250
250
250
3)
2
10
10
10
10
16
16
10
10
10
25
25
25
25
25
25
35
63
63
80
80
80
80
63
63
80
125
125
125
125
125
160
160
160
160
160
2)
NH TYPE
3ND
aM
--
--
--
--
20
20
--
--
--
20
20
35
--
--
20
35
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
125
125
125
British
Standards
fuses
BS88
--
--
--
--
35
35
--
--
--
35
35
50
--
--
35
50
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
125
125
125

Related parts for 3UG4622-1AW30