MAX16048ETN+ Maxim Integrated Products, MAX16048ETN+ Datasheet - Page 50

IC EE-PROG SYS MGR 8CH 56-TQFN

MAX16048ETN+

Manufacturer Part Number
MAX16048ETN+
Description
IC EE-PROG SYS MGR 8CH 56-TQFN
Manufacturer
Maxim Integrated Products
Type
System Managerr
Datasheet

Specifications of MAX16048ETN+

Number Of Voltages Monitored
8
Output
Open Drain, Push-Pull
Reset
Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
Adjustable/Selectable
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
56-TQFN
Manual Reset
Resettable
Watchdog
Yes
Supply Voltage (max)
14 V
Supply Voltage (min)
3 V
Supply Current (typ)
6500 uA
Maximum Power Dissipation
3810 mW
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
The acknowledge bit (ACK) is the 9th bit attached to
any 8-bit data word. The receiving device always gen-
erates an ACK. The MAX16046/MAX16048 generate an
ACK when receiving an address or data by pulling SDA
low during the 9th clock period (Figure 11). When
transmitting data, such as when the master device
reads data back from the MAX16046/MAX16048, the
device waits for the master device to generate an ACK.
Monitoring ACK allows for detection of unsuccessful
data transfers. An unsuccessful data transfer occurs if
the receiving device is busy or if a system fault has
occurred. In the event of an unsuccessful data transfer,
the bus master should reattempt communication at a
later time. The MAX16046/MAX16048 generate a NACK
after the command byte received during a software
reboot, while writing to the EEPROM, or when receiving
an illegal memory address.
Figure 11. Acknowledge
50
TRANSMITTER
RECEIVER
______________________________________________________________________________________
SDA BY
SDA BY
SCL
S
1
Acknowledge
2
Use the slave address input, A0, to allow multiple identi-
cal devices to share the same serial bus. Connect A0 to
GND, DBP (or an external supply voltage greater than
2V), SCL, or SDA to set the device address on the bus.
See Table 31 for a listing of all possible 7-bit addresses.
Table 31. Setting the I
Address
X = Don’t care, R = Read/write select bit
CLOCK PULSE FOR ACKNOWLEDGE
SDA
SCL
A0
0
1
8
2
SLAVE ADDRESS
C/SMBus Slave
1010 00XR
1010 01XR
1010 10XR
1010 11XR
NACK
ACK
9
Slave Address

Related parts for MAX16048ETN+