IC EE-PROG SYS MGR 8CH 56-TQFN

MAX16048ETN+

Manufacturer Part Number
MAX16048ETN+
Description
IC EE-PROG SYS MGR 8CH 56-TQFN
Manufacturer
Maxim Integrated Products
Type
System Managerr
Datasheet

Specifications of MAX16048ETN+

Number Of Voltages Monitored
8
Output
Open Drain, Push-Pull
Reset
Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
Adjustable/Selectable
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
56-TQFN
Manual Reset
Resettable
Watchdog
Yes
Supply Voltage (max)
14 V
Supply Voltage (min)
3 V
Supply Current (typ)
6500 uA
Maximum Power Dissipation
3810 mW
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 23. Critical Fault Configuration and Enable Bits
System Managers with Nonvolatile Fault Registers
REGISTER/
ADDRESS
EEPROM
4Ah
4Bh
47h
48h
49h
12-Channel/8-Channel EEPROM-Programmable
______________________________________________________________________________________
BIT RANGE
[1:0]
[7:2]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
Critical Fault Log Control
00 = Failed lines and ADC conversion values save to EEPROM upon critical fault
01 = Failed line flags only saved to EEPROM upon critical fault
10 = ADC conversion values only saved to EEPROM upon critical fault
11 = No information saved upon critical fault
Not used
1 = Fault log triggered when MON1 is below its undervoltage threshold
1 = Fault log triggered when MON2 is below its undervoltage threshold
1 = Fault log triggered when MON3 is below its undervoltage threshold
1 = Fault log triggered when MON4 is below its undervoltage threshold
1 = Fault log triggered when MON5 is below its undervoltage threshold
1 = Fault log triggered when MON6 is below its undervoltage threshold
1 = Fault log triggered when MON6 is below its undervoltage threshold
1 = Fault log triggered when MON8 is below its undervoltage threshold
1 = Fault log triggered when MON9 is below its undervoltage threshold*
1 = Fault log triggered when MON10 is below its undervoltage threshold*
1 = Fault log triggered when MON11 is below its undervoltage threshold*
1 = Fault log triggered when MON12 is below its undervoltage threshold*
1 = Fault log triggered when MON1 is above its overvoltage threshold
1 = Fault log triggered when MON2 is above its overvoltage threshold
1 = Fault log triggered when MON3 is above its overvoltage threshold
1 = Fault log triggered when MON3 is above its overvoltage threshold
1 = Fault log triggered when MON5 is above its overvoltage threshold
1 = Fault log triggered when MON6 is above its overvoltage threshold
1 = Fault log triggered when MON7 is above its overvoltage threshold
1 = Fault log triggered when MON8 is above its overvoltage threshold
1 = Fault log triggered when MON9 is above its overvoltage threshold*
1 = Fault log triggered when MON10 is above its overvoltage threshold*
1 = Fault log triggered when MON11 is above its overvoltage threshold*
1 = Fault log triggered when MON12 is above its overvoltage threshold*
1 = Fault log triggered when MON1 is above/below its early earning threshold
1 = Fault log triggered when MON2 is above/below its early warning threshold
1 = Fault log triggered when MON3 is above/below its early warning threshold
1 = Fault log triggered when MON4 is above/below its early warning threshold
1 = Fault log triggered when MON5 is above/below its early warning threshold
1 = Fault log triggered when MON6 is above/below its early warning threshold
1 = Fault log triggered when MON7 is above/below its early warning threshold
1 = Fault log triggered when MON8 is above/below its early warning threshold
DESCRIPTION
41