MAX16048ETN+ Maxim Integrated Products, MAX16048ETN+ Datasheet - Page 44

IC EE-PROG SYS MGR 8CH 56-TQFN

MAX16048ETN+

Manufacturer Part Number
MAX16048ETN+
Description
IC EE-PROG SYS MGR 8CH 56-TQFN
Manufacturer
Maxim Integrated Products
Type
System Managerr
Datasheet

Specifications of MAX16048ETN+

Number Of Voltages Monitored
8
Output
Open Drain, Push-Pull
Reset
Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
Adjustable/Selectable
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
56-TQFN
Manual Reset
Resettable
Watchdog
Yes
Supply Voltage (max)
14 V
Supply Voltage (min)
3 V
Supply Current (typ)
6500 uA
Maximum Power Dissipation
3810 mW
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The reset output, RESET, is asserted during power-
up/power-down and deasserts following the reset time-
out period once the power-up sequence is complete.
The power-up sequence is complete when any MON_
inputs assigned to Slot 12 exceed their undervoltage
thresholds. If no MON_ inputs are assigned to Slot 12,
the power-up sequence is complete after the slot
sequence delay is expired.
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
Table 26. EEPROM Fault Log Operation Period
Table 27. RESET Configuration and Dependencies
44
REGISTER/
FAULT CONTROL
ADDRESS
EEPROM
______________________________________________________________________________________
19h
REGISTER
r47h[1:0]
00
01
10
11
BIT RANGE
[1:0]
[6:4]
[2]
[3]
[7]
Failed lines and ADC values saved
RESET OUTPUT CONFIGURATION
00 = RESET is asserted if at least one of the selected inputs exceeds its undervoltage
threshold
01 = RESET is asserted if at least one of the selected inputs exceeds its early warning
threshold
10 = RESET is asserted if at least one of the selected inputs exceeds its overvoltage threshold
11 = RESET is asserted if any of the selected inputs exceeds undervoltage or overvoltage
thresholds
0 = RESET is an active-low output
1 = RESET is an active-high output
0 = RESET is a push-pull output
1 = RESET is an open-drain output
RESET TIMEOUT
000 = 25µs
001 = 2ms
010 = 25ms
011 = 100ms
100 = 200ms
101 = 400ms
110 = 800ms
111 = 1600ms
Reserved
No information saved
ADC values saved
Failed lines saved
DESCRIPTION
RESET
RESET is a configurable output that monitors selected
MON_ voltages during normal operation. RESET also
depends on any monitoring input that has one or more
critical fault enable bits set. Use r19h[1:0] to configure
RESET to assert on an overvoltage fault, undervoltage
fault, or both. Use r19h[3:2] to configure RESET as an
active-high/active-low push-pull/open-drain output. If
desired, configure GPIO4 as a manual reset input, MR,
and pull MR low to assert RESET. RESET includes a
programmable timeout. See Table 27 for RESET depen-
dencies and configuration registers.
DESCRIPTION
MINIMUM REQUIRED SHUTDOWN PERIOD
(ms)
204
168
N/A
60

Related parts for MAX16048ETN+