C8051F523A-IM Silicon Laboratories Inc, C8051F523A-IM Datasheet - Page 191

IC 8051 MCU 4K FLASH 10DFN

C8051F523A-IM

Manufacturer Part Number
C8051F523A-IM
Description
IC 8051 MCU 4K FLASH 10DFN
Manufacturer
Silicon Laboratories Inc
Series
C8051F52xr
Datasheets

Specifications of C8051F523A-IM

Program Memory Type
FLASH
Program Memory Size
4KB (4K x 8)
Package / Case
10-DFN
Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
6
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.25 V
Data Converters
A/D 6x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Processor Series
C8051F5x
Core
8051
Data Bus Width
8 bit
Data Ram Size
256 B
Interface Type
SPI/UART
Maximum Clock Frequency
25 MHz
Number Of Programmable I/os
6
Number Of Timers
3
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051F500DK
Minimum Operating Temperature
- 40 C
On-chip Adc
6-ch x 12-bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1488 - KIT DEV C8051F53XA, C8051F52XA770-1006 - ISP 4PORT FOR SILABS C8051F MCU336-1455 - ADAPTER PROGRAM TOOLSTICK F520
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1491-5
18.2.3. External Capture Mode
Capture Mode allows the external oscillator to be measured against the system clock. Timer 2 can be
clocked from the system clock, or the system clock divided by 12, depending on the T2ML (CKCON.4) and
T2XCLK bits. When a capture event is generated, the contents of Timer 2 (TMR2H:TMR2L) are loaded
into the Timer 2 reload registers (TMR2RLH:TMR2RLL) and the TF2H flag is set. A capture event is gener-
ated by the falling edge of the clock source being measured, which is the external oscillator/8. By recording
the difference between two successive timer capture values, the external oscillator frequency can be
determined with respect to the Timer 2 clock. The Timer 2 clock should be much faster than the capture
clock to achieve an accurate reading. Timer 2 should be in 16-bit auto-reload mode when using Capture
Mode.
For example, if T2ML = 1b and TF2CEN = 1b, Timer 2 will clock every SYSCLK and capture every external
clock divided by 8. If the SYSCLK is 24.5 MHz and the difference between two successive captures is
5984, then the external clock frequency is:
This mode allows software to determine the external oscillator frequency when an RC network or capacitor
is used to generate the clock source.
External Osc. / 8
SYSCLK / 12
Figure 18.6. Timer 2 Capture Mode Block Diagram
T2XCLK
1
0
24.5 MHz
------------------------
SYSCLK
5984 8 
M
H
T
3
M
T
3
L
C8051F52x/F52xA/F53x/F53xA
CKCON
M
T
2
H
External Osc. / 8
TF2CEN
M
T
2
L
1
0
=
M
T
1
M
T
0
0.032754 MHz or 32.754 kHz
S
C
A
1
S
C
A
0
TR2
Rev. 1.3
Capture
TCLK
TMR2RLH
TMR2H
TMR2RLL
TMR2L
TF2CEN
TR2CLK
TF2LEN
T2XCLK
TF2H
TF2L
TR2
Interrupt
191

Related parts for C8051F523A-IM