Notes: 1. When interrupts are accepted during user program execution and command
Note: For details on window function and command-line syntax, refer to the on-line help
6.5.8
1. Moving Source File Position after Creating Load Module
Rev. 2.0, 01/01, page 206 of 214
When the source file is moved after creating the load module, the [Open] dialog box may be
displayed to specify the source file during the debugging of the created load module. Select
the corresponding source file and click the [Open] button.
When no interrupt is processed during user program execution or in command input wait
state
While the emulator is executing the user program or is in command input wait state,
interrupts are not processed generally. However, if an internal interrupt or an edge
sensitive external interrupt occurs in command input wait state, the emulator holds the
interrupt and executes the interrupt processing routine when the GO command is entered.
When interrupts are processed during user program execution or in command input wait
state
To process non-maskable interrupts and peripheral module interrupts during emulator
command execution and in command input wait state, use the INTERRUPT command.
Input the INTERRUPT command into the command line window.
2. Use the NOP instruction at the delay slot after the RTE instruction in the
3. If a user interrupt is inserted while the user program breaks until the processing
function.
Notes on HDI
To process only non-maskable interrupts
Specify "nonmask" in the <interrupt_enable> option of the INTERRUPT command.
To process non-maskable interrupts and peripheral module interrupts
Specify "all" in the <interrupt_enable> option of the INTERRUPT command.
To switch to the mode in which no interrupt is processed:
Specify "disable" in the <interrupt_enable> option of the INTERRUPT command.
input wait state, user interrupt processing is not traced. In this case, continuous
trace cannot be enabled.
interrupt handler.
ends, do not set a BREAKPOINT in the interrupt handler. The emulator may
generate a Communication Timeout error. Use the Break Condition function.