EVAL-ADT7470EB Analog Devices Inc, EVAL-ADT7470EB Datasheet - Page 32

BOARD EVALUATION FOR ADT7470

EVAL-ADT7470EB

Manufacturer Part Number
EVAL-ADT7470EB
Description
BOARD EVALUATION FOR ADT7470
Manufacturer
Analog Devices Inc
Datasheet

Specifications of EVAL-ADT7470EB

Sensor Type
Temperature
Interface
SMBus (2-Wire/I²C)
Voltage - Supply
3 V ~ 5.5 V
Embedded
No
Utilized Ic / Part
ADT7470
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
ADT7470
Table 34. Register 0x43. Fan Pulses per Revolution Register (Power-On Default = 0x55).
Bit Name
[1:0] Fan 1
[3:2] Fan 2
[5:4] Fan 3
[7:6] Fan 4
Table 35. Register 0x44 to Register 0x57. Temperature Limit Registers.
Register Address
0x44
0x45
0x46
0x47
0x48
0x49
0x4A
0x4B
0x4C
0x4D
0x4E
0x4F
0x50
0x51
0x52
0x53
0x54
0x55
0x56
0x57
Exceeding any of the temperature limits shown in Table 35 by 1°C causes the appropriate status bit to be set in the interrupt status registers.
High limits: An interrupt is generated when a value exceeds its high limit (> comparison).
Low limits: An interrupt is generated when a value is equal to or below its low limit (≤ comparison).
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Description
Sets the number of pulses to be counted when measuring Fan 1 speed.
Can be used to determine fan’s pulses per revolution number for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Sets the number of pulses to be counted when measuring Fan 2 speed.
Can be used to determine fan’s pulses per revolution number for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Sets the number of pulses to be counted when measuring Fan 3 speed.
Can be used to determine fan’s pulses per revolution for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Sets the number of pulses to be counted when measuring Fan 4 speed. Can be used to determine fan’s
pulses per revolution for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Description
Temperature 1 low limit
Temperature 1 high limit
Temperature 2 low limit
Temperature 2 high limit
Temperature 3 low limit
Temperature 3 high limit
Temperature 4 low limit
Temperature 4 high limit
Temperature 5 low limit
Temperature 5 high limit
Temperature 6 low limit
Temperature 6 high limit
Temperature 7 low limit
Temperature 7 high limit
Temperature 8 low limit
Temperature 8 high limit
Temperature 9 low limit
Temperature 9 high limit
Temperature 10 low limit
Temperature 10 high limit
Rev. C | Page 32 of 40
Power-On Default
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F