EVAL-ADT7467EB Analog Devices Inc, EVAL-ADT7467EB Datasheet - Page 47
EVAL-ADT7467EB
Manufacturer Part Number
EVAL-ADT7467EB
Description
BOARD EVALUATION FOR ADT7467
Manufacturer
Analog Devices Inc
Series
dBCool®r
Datasheet
1.EVAL-ADT7467EB.pdf
(80 pages)
Specifications of EVAL-ADT7467EB
Sensor Type
Temperature
Sensing Range
-40°C ~ 120°C
Interface
SMBus (2-Wire/I²C)
Sensitivity
±1.5°C
Voltage - Supply
3 V ~ 5.5 V
Embedded
No
Utilized Ic / Part
ADT7467
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
STEP 7: T
T
temperature channel. Above this temperature, a component
such as the CPU or VRM might be operating beyond its safe
operating limit. When the temperature measured exceeds
T
to provide critical system cooling.
Figure 66. T
THERM
THERM
100
100
90
80
70
60
50
40
30
20
10
90
80
70
60
50
40
30
20
10
, all fans are driven at 100% PWM duty cycle (full speed)
0
0
is the absolute maximum temperature allowed on a
0
0
RANGE
THERM
10
10
and Percentage of Fan Speed Slopes for VRM, Ambient, and
20
20
FOR TEMPERATURE CHANNELS
CPU Temperature Channels
TEMPERATURE ABOVE T
TEMPERATURE ABOVE T
30
30
40
40
50
50
60
60
70
MIN
70
MIN
80
80
90
90
100
100
Rev. A| Page 47 of 80
The fans remain running at 100% until the temperature drops
below T
programmed into the Hysteresis Registers 0x6D and 0x6E. The
default hysteresis value is 4°C.
The T
operating temperature of the system. Because exceeding any
T
acoustic effects. Ultimately, this limit should be set up as a fail-
safe, and users should ensure that it is not exceeded under
normal system operating conditions.
Note that the T
speed regardless of the configuration of the automatic fan
control settings. This allows some flexibility, because a T
value can be selected based on its slope, and a hard limit (such
as 70°C) can be programmed as T
the fan reaches full speed) by setting T
example, 70°C).
THERM Registers
Reg. 0x6A, Remote 1 THERM limit = 0xA4 (100°C default)
Reg. 0x6B, local THERM limit = 0xA4 (100°C default)
Reg. 0x6C, Remote 2 THERM limit = 0xA4 (100°C default)
Hysteresis Registers
Reg. 0x6D, Remote 1, local hysteresis register
<7:4>, Remote 1 temperature hysteresis (4°C default).
<3:0>, local temperature hysteresis (4°C default).
Reg. 0x6E, Remote 2 temperature hysteresis register
<7:4>, Remote 2 temperature hysteresis (4°C default).
Because each hysteresis setting is four bits, hysteresis values are
programmable from 1°C to 15°C. It is recommended that
hysteresis values are not programmed to 0°C because this
disables hysteresis. In effect, this would cause the fans to cycle
between normal speed and 100% speed, creating unsettling
acoustic noise.
THERM
THERM
limit runs all fans at 100%, it has significant negative
THERM
limit should be considered the maximum worst-case
minus hysteresis, where hysteresis is the number
THERM
limits are nonmaskable and affect the fan
MAX
(the temperature at which
THERM
to that limit (for
ADT7467
RANGE