BOARD EVAL FOR AD7147ACPZ

EVAL-AD7147EBZ

Manufacturer Part Number
EVAL-AD7147EBZ
Description
BOARD EVAL FOR AD7147ACPZ
Manufacturer
Analog Devices Inc
Series
CapTouch™r

Specifications of EVAL-AD7147EBZ

Sensor Type
Touch, Capacitive
Interface
SPI Serial
Voltage - Supply
2.6 V ~ 3.6 V
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
AD7147
Silicon Manufacturer
Analog Devices
Application Sub Type
CapTouch Controller
Kit Application Type
Data Converter
Silicon Core Number
AD7147
Kit Contents
CapTouch Evaluation Board, USB Cable
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sensitivity
-
Sensing Range
-
Lead Free Status / Rohs Status
Compliant
AD7147
Table 36. STAGEx_AFE_OFFSET Register Description (x = 0 to 11)
Data Bit
[5:0]
[6]
[7]
[13:8]
[14]
[15]
Table 37. STAGEx_SENSITIVITY Register Description (x = 0 to 11)
Data Bit
[3:0]
[6:4]
[7]
[11:8]
[14:12]
[15]
Default
Value
X
X
X
X
X
X
Default
Value
X
X
X
X
X
X
Type
R/W
R/W
R/W
R/W
Type
R/W
R/W
R/W
R/W
R/W
R/W
NEG_AFE_OFFSET
Unused
NEG_AFE_OFFSET_SWAP
POS_AFE_OFFSET
Unused
POS_AFE_OFFSET_SWAP
Unused
POS_THRESHOLD_SENSITIVITY
POS_PEAK_DETECT
Unused
Name
Name
NEG_THRESHOLD_SENSITIVITY
NEG_PEAK_DETECT
Rev. B | Page 54 of 72
Description
Negative AFE offset setting (20 pF range)
1 LSB value = 0.32 pF of offset
Set to 0
Negative AFE offset swap control
0 = NEG_AFE_OFFSET applied to CDC negative input
1 = NEG_AFE_OFFSET applied to CDC positive input
Positive AFE offset setting (20 pF range)
1 LSB value = 0.32 pF of offset
Set to 0
Positive AFE offset swap control
0 = POS_AFE_OFFSET applied to CDC positive input
1 = POS_AFE_OFFSET applied to CDC negative input
Description
Negative threshold sensitivity control
0000 = 25%, 0001 = 29.73%, 0010 = 34.40%, 0011 = 39.08%
0100 = 43.79%, 0101 = 48.47%, 0110 = 53.15%
0111 = 57.83%, 1000 = 62.51%, 1001 = 67.22%
1010 = 71.90%, 1011 = 76.58%, 1100 = 81.28%
1101 = 85.96%, 1110 = 90.64%, 1111 = 95.32%
Negative peak detect setting
000 = 40% level, 001 = 50% level, 010 = 60% level
011 = 70% level, 100 = 80% level, 101 = 90% level
Set to 0
Positive threshold sensitivity control
0000 = 25%, 0001 = 29.73%, 0010 = 34.40%, 0011 = 39.08%
0100 = 43.79%, 0101 = 48.47%, 0110 = 53.15%
0111 = 57.83%, 1000 = 62.51%, 1001 = 67.22%
1010 = 71.90%, 1011 = 76.58%, 1100 = 81.28%
1101 = 85.96%, 1110 = 90.64%, 1111 = 95.32%
Positive peak detect setting
000 = 40% level, 001 = 50% level, 010 = 60% level
011 = 70% level, 100 = 80% level, 101 = 90% level
Set to 0