LP5521TMEV National Semiconductor, LP5521TMEV Datasheet - Page 21

no-image

LP5521TMEV

Manufacturer Part Number
LP5521TMEV
Description
EVAL BOARD FOR LP5521
Manufacturer
National Semiconductor
Datasheets

Specifications of LP5521TMEV

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q5109809
X means do not care whether 1 or 0.
Trigger
Wait or send triggers can be used to e.g. synchronize opera-
tion between different channels. Send trigger command takes
sixteen 32 kHz clock cycles and wait for trigger takes at least
sixteen 32 kHz clock cycles. The receiving channel stores
sent triggers. Received triggers are cleared by wait for trigger
command if received triggers match to channels defined in
the command. Channel waits for until all defined triggers have
been received.
External trigger input signal must be at least two 32 kHz clock
cycles (= 61 μs typ.) long to be recognized. Trigger output
X means do not care whether 1 or 0.
15
1
14
1
send trigger<5:0>
wait trigger<5:0>
13
1
Name
Name
reset
int
EXT
12
11
Value
Value(d)
0
1
0
1
wait trigger <5:0>
X
0-31
0-31
10
No interrupt will be sent.
Send interrupt to processor by pulling the INT pin down and
setting corresponding status register bit high to notify that
program has ended. Interrupt can only be cleared by reading
interrupt status register 0CH.
Keep the current PWM value.
Set PWM value to 0.
B
9
Wait for trigger for the channel(s) defined. Several triggers can
be defined in the same command. Bit 0 is R, bit 1 is G, bit 2 is B
and bit 5 is external trigger I/O. Bits 3 and 4 are not in use.
Send trigger for the channel(s) defined. Several triggers can be
defined in the same command. Bit 0 is R, bit 1 is G, bit 2 is B and
bit 5 is external trigger I/O. Bits 3 and 4 are not in use.
Trigger command
G
8
21
R
7
signal is three 32 kHz clock cycles (92 μs typ.) long. External
trigger signal is active low, i.e. when trigger is sent/received
the pin is pulled to GND. Sent external trigger is masked, i.e.
the device which has sent the trigger will not recognize it. If
send and wait external trigger are used on the same com-
mand, the send external trigger is executed first, then the wait
external trigger.
Description
EXT
6
Description
5
send trigger <5:0>
X
4
B
3
G
2
R
1
www.national.com
X
0