STEVAL-ISA056V1 STMicroelectronics, STEVAL-ISA056V1 Datasheet - Page 28

BOARD EVAL BASED ON PM6600

STEVAL-ISA056V1

Manufacturer Part Number
STEVAL-ISA056V1
Description
BOARD EVAL BASED ON PM6600
Manufacturer
STMicroelectronics
Type
PWM Controllersr
Datasheets

Specifications of STEVAL-ISA056V1

Design Resources
STEVAL-ISA056V1 Gerber Files STEVAL-ISA056V1 Schematic STEVAL-ISA056V1 Bill of Material
Current - Output / Channel
30mA
Outputs And Type
6, Non-Isolated
Voltage - Output
36 V
Features
Dimmable
Voltage - Input
4.5 ~ 28V
Utilized Ic / Part
PM6600
Input Voltage
4.5 V to 28 V
Output Voltage
36 V
Product
Power Management Modules
Core Chip
PM6600
Topology
Boost
No. Of Outputs
1
Dimming Control Type
PWM
Mcu Supported Families
PM6600
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
PM6600
Other names
497-8414

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-ISA056V1
Manufacturer:
STMicroelectronics
Quantity:
1
Operation description
7.3
28/60
Figure 44. OVP threshold setting
Switching frequency selection and synchronization
The switching frequency of the boost converter can be set in the 200 kHz-1 MHz range by
connecting the FSW pin to ground through a resistor. Calculation of the setting resistor is
made using equation 3 and should not exceed the 80 kΩ-400 kΩ range.
Equation 6
In addition, when the FSW pin is tied to AVCC, the PM6600 uses a default 660 kHz fixed
switching frequency, allowing to save a resistor in minimum components-count applications.
Figure 45. Multiple device synchronization
The FSW pin can also be used as a synchronization input, allowing the PM6600 to operate
both as master or slave device. If a clock signal with a 210 kHz minimum frequency is
applied to this pin, the device locks synchronized (300 mV threshold). An Internal time-out
allows synchronization as long as the external clock frequency is greater than 210 kHz.
Keeping the FSW pin voltage lower than 300 mV for more than 1/210 kHz
the device turn off. Normal operation is resumed as soon as FSW rises above the
mentioned threshold and the soft-start sequence is repeated.
R
FSW
FSW
AVCC
V
IN
PM6600
MASTER
SGND
Doc ID 14248 Rev 7
PM6600
SYNC
R
SGND
FSW
LX
OVSEL
=
f
2
SW
5 .
FSW
R
R
2
1
PM6600
V
SLAVE
OUT
C
C
SYNC
13
10
SGND
C
OUT
SYNC
5 μs results in
Sync Out
PM6600

Related parts for STEVAL-ISA056V1