EVL6564-100W STMicroelectronics, EVL6564-100W Datasheet - Page 25

BOARD EVAL PFC FOR L6564D

EVL6564-100W

Manufacturer Part Number
EVL6564-100W
Description
BOARD EVAL PFC FOR L6564D
Manufacturer
STMicroelectronics
Type
Power Factor Correctionr
Datasheets

Specifications of EVL6564-100W

Main Purpose
AC/DC, Primary Side
Outputs And Type
1, Non-Isolated
Power - Output
100W
Voltage - Output
400V
Voltage - Input
90 ~ 265VAC
Regulator Topology
Boost
Frequency - Switching
40kHz
Board Type
Fully Populated
Utilized Ic / Part
L6564
Input Voltage
90 V to 265 V
Output Voltage
400 V
Dimensions
90 mm x 83 mm
Product
Power Management Modules
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Current - Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
L6564
Other names
497-10164

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EVL6564-100W
Manufacturer:
ST
0
L6564
6.6
Power management/housekeeping functions
A communication line with the control IC of the cascaded dc-dc converter can be
established via the disable function included in the PFC_OK pin (see “Feedback failure
protection” section for more details). Typically this line is used to allow the PWM controller of
the cascaded dc-dc converter to shut down the L6564 in case of light load and to minimize
the no-load input consumption. Should the residual consumption of the chip be an issue, it is
also possible to cut down the supply voltage. Interface circuits like those are shown in figure
32. Needless to say, this operation assumes that the cascaded dc-dc converter stage works
as the master and the PFC stage as the slave or, in other words, that the dc-dc stage starts
first, it powers both controllers and enables/disables the operation of the PFC stage.
Figure 33. Interface circuits that let dc-dc converter's controller IC disable the L6564
Another function available is the brownout protection which is basically a not-latched
shutdown function that is activated when a condition of mains under voltage is detected.
This condition may cause overheating of the primary power section due to an excess of
RMS current. Brownout can also cause the PFC pre-regulator to work open loop and this
could be dangerous to the PFC stage itself and the downstream converter, should the input
voltage return abruptly to its rated value. Another problem is the spurious restarts that may
occur during converter power down and that cause the output voltage of the converter not to
decay to zero monotonically. For these reasons it is usually preferable to shutdown the unit
in case of brownout. Brownout threshold is internally fixed at 0.8V and is sensed on pin VFF
(5) during the voltage falling and 80 mV threshold hysteresis prevents from rebounding at
input voltage turn off. In
mentioned working conditions that cause the device to stop operating.
Table 5
Doc ID 16202 Rev 2
it is possible to find a summary of all of the above
Application information
25/33

Related parts for EVL6564-100W