FPSS1U TDK Corporation, FPSS1U Datasheet - Page 22

RACK 3 SLOT FOR FPS1000

FPSS1U

Manufacturer Part Number
FPSS1U
Description
RACK 3 SLOT FOR FPS1000
Manufacturer
TDK Corporation
Series
FPSr
Datasheets

Specifications of FPSS1U

Accessory Type
Rack System
No. Of Slots
3
Peak Reflow Compatible (260 C)
No
External Width
19.00"
Rack U Height
1
External Depth
13.82"
For Use With
285-1239 - PWR SUP FNT END 48V 1008W 21A285-1238 - PWR SUP FNT END 32V 992W 31A285-1237 - PWR SUP FNT END 24V 960W 40A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
FPS1000 Series
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1240

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FPSS1U
Manufacturer:
TDK-LAMBDA
Quantity:
232
Part Number:
FPSS1U/P
Manufacturer:
TDK-LAMBDA
Quantity:
232
CHAPTER 7
7.1 Introduction
The I
are then transferred to the host PC if demanded, over a standard I
The following data can be monitored for the individual units connected to the I
1. Status of the unit.
2. Actual output voltage, output current and internal temperature of the unit.
3. Manufacturing related data (model, serial number, manufacturing date etc…).
7.1.1 Addressing (A0, A1, A2).
Three address lines allow up to eight FPS1000 units to be addressed on a single I
internally pulled-up to +5V by resistors. Addressing of a unit is achieved by hard-wiring an address line to the
-Sense to set it to "0" or leaving the address line open to set it to "1".
7.1.2 Serial clock
This line is clocked by the processor which controls the I
via a pull-up resistor of 2KΩ. The I
7.1.3 Serial dataThis line is a bidirectional data line. It should be connected to +5V
(referenced to -Sense) via a pull-up resistor of 2KΩ.
7.2 I
7.2.1 General specifications
1. Clock frequency:
2. Address lines:
7.2.2 Output voltage measurement
1. Measurement accuracy:
2. Measurement resolution:
3. Measurement range:
7.2.3 Output current measurement
1. Measurement accuracy:
2. Measurement resolution:
3. Measurement range:
7.2.4 Internal temperature measurement
1. Measurement accuracy:
2. Measurement resolution:
3. Measurement range:
7.2.5 EEPROM
1. EEPROM type:
2. EEPROM data:
7.2.6 Status register
1. Register type:
2. Register content:
2
2
C Interface Specifications
C interface option includes facilities to monitor operating parameters of the power supply. The parameters
I
2
C BUS INTERFACE OPTION
The I
referenced to the -Sense potential. When using series
connection of FPS1000 units, do not connect the I
of the units together.
2
C interface is designed to run with a serial clock speed of 100KHz.
2
C bus address lines, serial clock and data are
0~60.0V for 48V model / 0~40.0V for 32V model / 0-30.0V for 24V model.
100KHz
Three (A0, A1, A2). Support 8 power supply modules
+/-2% of full scale
8 bits
+/-10% of full scale
8 bits
+/-3°C
8 bits
0-100°C
AT24C02AN-10S , Atmel, or equivalent
Model name, Serial no., Revision, Manufacture. Name, Output voltage,
Date, Country of manufacturing, Check-Sum
PCF8574, Philips, or equivalent.
DC Fail, Over-Temperature Protection (OTP)
Temperature Alarm, Fan Fail, AC Fail
0~25.0A for 48V model / 0~50A for 32V & 24V models
CAUTION
2
C bus. It should be connected to +5V (referenced to -Sense)
19
2
C bus.
2
FPS1000 Instruction Manual
C bus:
2
2
C lines
C bus. The address lines are