M0120SD-201MDBR1-1 Newhaven Display, M0120SD-201MDBR1-1 Datasheet - Page 13

no-image

M0120SD-201MDBR1-1

Manufacturer Part Number
M0120SD-201MDBR1-1
Description
MODULE VF CHAR 1X20 4.9MM
Manufacturer
Newhaven Display
Datasheet

Specifications of M0120SD-201MDBR1-1

Outline L X W X H
150.00mm x 32.00mm x 25.50mm
Viewing Area
92.70mm L x 4.90mm W
Display Format
20 x 1
Display Type
Character
Format
5 x 7 Dots
Voltage - Supply
4.5 V ~ 5.5 V
Character Size
4.90mm H x 3.40mm W
Operating Temperature
-20°C ~ 70°C
Product
Character Display Modules
Character Count X Line
20 x 1
Module Size (w X H X T)
150 mm x 32 mm x 25.5 mm
Voltage Rating
4.5 V to 5.5 V
Operating Temperature Range
- 20 C to + 70 C
Dot Format
5 x 7
Viewing Area (w X H)
92.7 mm x 4.9 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interface
-
Number Of Dots
-
Lead Free Status / Rohs Status
 Details
Note Be sure the controller is not in the busy state (BF=0) before sending an instruction from the MPU to the
6.1 Outline
Only the instruction register (IR) and data register (DR) of the VFD controller can be controlled by the
user's MPU. Before starting the internal operation of the controller, control information is temporarily
stored into these registers to allow interfacing with various MPUs, which operate at different speeds, or
various peripheral control devices. The internal operation of the controller is determined by signals sent
from the MPU. These signals, which include register selection signal (RS), read/write signal (R/W), and
the data bus (DB0 to DB7), make up the controller instructions (See Table-13). There are four categories
of instructions that:
However, auto-increment by 1 (or auto-decrement by 1) of internal RAM addresses after each data write
can lighten the program load of the MPU. Since the display shift instruction can perform concurrently with
display data write, the user can minimize system development time with maximum programming
efficiency
When an instruction is being executed for internal operation, no instruction other than the busy
flag/address read instruction can be executed. Because the busy flag is set to 1 while an instruction is being
executed, check it to make sure it is 0 before sending another instruction from the MPU.
Normally instructions that perform data transfer with interval RAM are used the most.
nodule. If an instruction is sent without checking the busy flag, the time between the first instruction and
next instruction will take much longer than the instruction time itself.
Refer to Table-13 for the list of each instruction execution time.
designate controller functions, such as display format, data length, ect.
Set internal RAM addresses
Perform data transfer with internal RAM
Perform miscellaneous functions