VK162-12 Matrix Orbital, VK162-12 Datasheet - Page 19

VFD DISPLAY 16X2 SER/I2C

VK162-12

Manufacturer Part Number
VK162-12
Description
VFD DISPLAY 16X2 SER/I2C
Manufacturer
Matrix Orbital
Series
VK162-12r
Datasheet

Specifications of VK162-12

Outline L X W X H
80.00mm x 36.00mm x 12.70mm
Viewing Area
51.40mm L x 11.40mm W
Display Format
16 x 2
Display Type
Character
Format
5 x 7 Dots
Character Size
4.76mm H x 2.46mm W
Interface
Serial
Operating Temperature
-20°C ~ 70°C
Product
Character Display Modules
Character Count X Line
16 x 2
Module Size (w X H X T)
80 mm x 36 mm x 12.7 mm
Operating Temperature Range
- 20 C to + 70 C
Dot Format
5 x 7
Viewing Area (w X H)
51.4 mm x 11.4 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Number Of Dots
-
Lead Free Status / Rohs Status
 Details
Other names
635-1014
4.1.2 I
sequence. To begin a transaction the data line, SDA, must toggle from high to low while the clock line, SCL,
is high. Next, the display must be addressed using a one byte hexadecimal value, the default to write to the
unit is 0x50, while read is 0x51. Then information can be sent to the unit; even when reading, a command
must first be sent to let the unit know what type of information it is required to return. After each bit is sent,
the display will issue an ACK or NACK as described above. Finally, when communication is complete, the
transaction is ended by toggling the data line from low to high while the clock line is high. An example of
the use of this algorithm to write a simple “HELLO” message can be seen in 3.
4.1.3 Serial Communication
RS-232 protocol at at a default baud rate of 19,200 bps and is capable of standard baud rates from 9600
to 115,200 bps. Furthermore the VK162-12 is also capable of reproducing any non-standard baud rate in
between using values entered into our baud rate generation algorithm and set through command 164 (0xA4).
The display module communicates at standard voltage levels of -30V to +30V or at TTL levels of 0 to +5V
by setting the Protocol Select Jumpers to TTL.
4.2 Changing the I
Matrix Orbital
The typical I
In addition to being able to communicate via I
Syntax
Parameters
NOTE These delays are consrevative, and may be decreased based on performance
2
C Transaction Example
2
C transaction contains four parts: the start sequence, addressing, information, and stop
Hexadecimal
Decimal
ASCII
Parameter
adr
Information
2
C Slave Address
Address
START
STOP
Table 3: I
2
0xFE 0x33 [adr]
254 51 [adr]
254 “3” [adr]
C Transaction Algorithm
0x48 0x45 0x4C 0x4C 0x4F
VK162-12
Length
Toggle SDA high to low
Toggle SDA low to high
2
1
C the VK162-12 communicates natively through the
0x50
Description
The new I
0xFF).
2
C write address (0x00 -
15