IDT72P51539L6BB IDT, Integrated Device Technology Inc, IDT72P51539L6BB Datasheet - Page 27

no-image

IDT72P51539L6BB

Manufacturer Part Number
IDT72P51539L6BB
Description
IC FLOW CTRL 36BIT 256-BGA
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT72P51539L6BB

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
72P51539L6BB

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT72P51539L6BB
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT72P51539L6BB8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT72P51539L6BBI
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT72P51539L6BBI8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
TABLE 5 — READ ADDRESS BUS, RDADD[7:0]
READ QUEUE SELECTION AND READ OPERATION
(STANDARD MODE)
trol devices can be configured up to a maximum of 32 queues which data can
be read via a common read port using the data outputs (Qout), read clock
(RCLK) and read enable (REN). An output enable, OE control pin is also
provided to allow High-Impedance selection of the Qout data outputs. The multi-
queue device read port operates in standard IDT mode and “First Word Fall
Through” mode (see Figure 46, Write Operations in First Word Fall Through).
The queue to be read is selected by the address presented on the read address
bus (RDADD) during a rising edge on RCLK while read address enable
(RADEN) is HIGH. The state of REN does not impact the queue selection. The
queue selection requires 1 RCLK cycles. All subsequent data reads will be from
this queue until another queue is selected.
device. The read port is designed such that 100% bus utilization can be
IDT72P51539/72P51549/72P51559/72P51569 1.8V, MQ FLOW-CONTROL DEVICES
(32 QUEUES) 36 BIT WIDE CONFIGURATION 589, 824, 1,179,648, 2,359,296, and 4,718,592
The IDT72P51539/72P51549/72P51559/72P51569 multi-queue flow-con-
Standard mode operation is defined as individual words will be read from the
Read Queue
PAEn/PRn
Quadrant
Operation RCLK
Select
Select
RADEN
1
0
Status Word
Address
0000
0001
0010
0011
27
ESTR
obtained. This means that data can be read out of the device on every RCLK
rising edge including the cycle that a new queue is being addressed.
(see Figure 48, Read Queue Select, Read Operation). RADEN goes high
signaling a change of queue (clock cycle “D”). The address on RDADD at that
time determines the next queue. Data presented during that cycle will be read.
Reading data can continue from the active, provided REN is LOW. If REN is
HIGH (inactive) for these two clock cycles, data will not be read from the queue.
If a new selected queue is empty, any reads from that queue will be prevented.
Data cannot be read from an empty queue. Remember that OE allows the user
to place the data output bus (Qout) into High-Impedance and the data can be
read in to the output register regardless of OE.
13, 15, and 16 for read queue selection and read port operation timing diagrams.
0
1
Changing queues requires a minimum of four RCLK cycles on the read port
Refer to Table 5, for Read Address Bus arrangement. Also, refer to Figures
Queue Status on PAEn/PRn Bus
Q0 : Q7 → PAF0 : PAF7
Q8 : Q15 → PAF0 : PAF7
Q16 : Q23 → PAF0 : PAF7
Q24 : Q31 → PAF0 : PAF7
Device Select
(Compared to
ID2,1,0)
Device Select
(Compared to
ID2,1,0)
7 6 5
7 6 5
RDADD[7:0]
Read Queue Address
(4 bits = 16 Queues
5 bits = 32 Queues)
X
4 3 2 1 0
4
3 2 1 0
Status Word
COMMERCIAL AND INDUSTRIAL
Address
6715 drw12
TEMPERATURE RANGES
FEBRUARY 13, 2009

Related parts for IDT72P51539L6BB