EVAL-ADM1276EBZ Analog Devices, EVAL-ADM1276EBZ Datasheet - Page 44

no-image

EVAL-ADM1276EBZ

Manufacturer Part Number
EVAL-ADM1276EBZ
Description
Power Management IC Development Tools EVALUATION BOARD
Manufacturer
Analog Devices
Type
Hot Swap & Power Distributionr
Series
ADM1276r
Datasheet

Specifications of EVAL-ADM1276EBZ

Rohs
yes
Tool Is For Evaluation Of
ADM1276
Input Voltage
20 V
Factory Pack Quantity
1
ADM1276
DEVICE_CONFIG
Code: 0xD8, read/write byte. Value after reset: 0x00.
Table 40. Bit Descriptions for DEVICE_CONFIG Command
Bits
[7]
[6]
[5]
[4]
[3:0]
POWER_CYCLE
Code: 0xD9, send byte, no data.
PEAK_PIN
Code: 0xDA, read/write word. Value after reset: 0x0000 (writing 0x0000 clears the peak value).
Table 41. Bit Descriptions for PEAK_PIN Command
Bits
[15]
[14:0]
READ_PIN_EXT
Code: 0xDB, block read. Value after reset: 0x03, 0x000000.
Table 42. Byte Descriptions for READ_PIN_EXT Command
Byte
[0]
[3:1]
READ_EIN_EXT
Code: 0xDC, block read. Value after reset: 0x08, 0x000000, 0x0000, 0x000000.
Table 43. Byte Descriptions for READ_EIN_EXT Command
Byte
[0]
[3:1]
[5:4]
[8:6]
Bit Name
OC_GLITCH_TIME
FLB_DISABLE
OPERATION_CMD_EN
IOUT_WARN2_SELECT
Reserved
Bit Name
Reserved
PEAK_PIN
Byte Name
Byte count
PIN extended
Byte Name
Byte count
Energy count extended
Rollover count extended
Sample count
Settings
0
1
0
1
0
1
0
1
0000
Settings
0
Value
0x03
0x000000
Value
0x08
0x000000
0x0000
0x000000
Description
Default. The long duration glitch filter is used when a severe overcurrent fault is
detected.
The short duration glitch filter is used when a severe overcurrent fault is detected.
Default. Foldback is enabled and can affect the hot swap current sense limit.
Foldback is disabled and does not affect the hot swap current sense limit. This setting
can be useful if the sole purpose of the FLB pin is to act as a power-good input.
Default. The OPERATION command is disabled, and the ADM1276 issues a no
acknowledge if the command is received. This setting provides some protection
against a card accidentally turning itself off.
The OPERATION command is enabled, and the ADM1276 responds to it.
Default. Configures IOUT_WARN2_LIMIT as an undercurrent threshold.
Configures IOUT_WARN2_LIMIT as an overcurrent threshold.
Always reads as 0000.
Description
Always reads as 0.
Returns the peak input power since the register was last cleared.
Description
Always reads as 0x03, the number of data bytes that the block read command
expects to read.
Result of the VIN × IOUT calculation that has not been truncated. Byte 3 is the high
byte, Byte 2 is the middle byte, and Byte 1 is the low byte.
Description
Always reads as 0x08, the number of data bytes that the block read command
expects to read.
24-bit energy accumulator in direct format. Byte 3 is the high byte, Byte 2 is the
middle byte, and Byte 1 is the low byte.
Number of times that the energy counter has rolled over from 0x7FFF to 0x0000.
This is a straight 16-bit binary value. Byte 5 is the high byte, and Byte 4 is the low
byte.
Total number of PIN samples acquired and accumulated in the energy count
accumulator. Byte 8 is the high byte, Byte 7 is the middle byte, and Byte 6 is the
low byte.
Rev. B | Page 44 of 48