EVAL-ADM1276EBZ Analog Devices, EVAL-ADM1276EBZ Datasheet - Page 38

no-image

EVAL-ADM1276EBZ

Manufacturer Part Number
EVAL-ADM1276EBZ
Description
Power Management IC Development Tools EVALUATION BOARD
Manufacturer
Analog Devices
Type
Hot Swap & Power Distributionr
Series
ADM1276r
Datasheet

Specifications of EVAL-ADM1276EBZ

Rohs
yes
Tool Is For Evaluation Of
ADM1276
Input Voltage
20 V
Factory Pack Quantity
1
ADM1276
STATUS_WORD
Code: 0x79, read word. Value after reset: 0x0000.
Table 20. Bit Descriptions for STATUS_WORD Command
Bits
[15]
[14]
[13]
[12]
[11]
[10:8]
[7:0]
STATUS_VOUT
Code: 0x7A, read byte. Value after reset: 0x00.
Table 21. Bit Descriptions for STATUS_VOUT Command
Bits
[7]
[6]
[5]
[4:0]
STATUS_IOUT
Code: 0x7B, read byte. Value after reset: 0x00.
Table 22. Bit Descriptions for STATUS_IOUT Command
Bits
[7]
[6]
[5]
[4:0]
Bit Name
VOUT_STATUS
IOUT_STATUS
INPUT_STATUS
MFR_STATUS
POWER_GOOD#
Reserved
STATUS_BYTE
Bit Name
Reserved
VOUT_OV_WARN
VOUT_UV_WARN
Reserved
Bit Name
IOUT_OC_FAULT
Reserved
IOUT_OC_WARN
Reserved
Behavior
Live
Live
Live
Live
Live
Behavior
Latched
Latched
Behavior
Latched
Latched
Settings
0
1
0
1
0
1
0
1
0
1
000
Settings
0
0
1
0
1
00000
Settings
0
1
0
0
1
00000
Rev. B | Page 38 of 48
Description
There are no active status bits to be read by STATUS_VOUT.
There are one or more active status bits to be read by STATUS_VOUT.
There are no active status bits to be read by STATUS_IOUT.
There are one or more active status bits to be read by STATUS_IOUT.
There are no active status bits to be read by STATUS_INPUT.
There are one or more active status bits to be read by STATUS_INPUT.
There are no active status bits to be read by STATUS_MFR_SPECIFIC.
There are one or more active status bits to be read by STATUS_MFR_SPECIFIC.
The voltage on the FLB pin is above the required threshold, indicating
that output power is considered good. This bit is the logical inversion of
the PWRGD pin on the part.
The voltage on the FLB pin is below the required threshold, indicating
that output power is considered bad.
Always reads as 000.
This byte is the same as the byte returned by the STATUS_BYTE command.
Description
Always reads as 0.
No overvoltage condition on the output supply detected by the power
monitor.
An overvoltage condition on the output supply was detected by the
power monitor.
No undervoltage condition on the output supply detected by the power
monitor.
An undervoltage condition on the output supply was detected by the
power monitor.
Always reads as 00000.
Description
No overcurrent output fault detected.
The hot swap controller detected an overcurrent condition and the time
limit set by the capacitor on the TIMER pin has elapsed, causing the hot
swap gate drive to shut down.
Always reads as 0.
No overcurrent condition on the output supply detected by the power
monitor using the IOUT_OC_WARN_LIMIT command.
An overcurrent condition was detected by the power monitor using the
IOUT_OC_WARN_LIMIT command.
Always reads as 00000.
Data Sheet

Related parts for EVAL-ADM1276EBZ