ZLF645E0H2864G00TR Maxim Integrated, ZLF645E0H2864G00TR Datasheet - Page 128

no-image

ZLF645E0H2864G00TR

Manufacturer Part Number
ZLF645E0H2864G00TR
Description
8-bit Microcontrollers - MCU Crimzon Flash Infrared MCU
Manufacturer
Maxim Integrated
Datasheet

Specifications of ZLF645E0H2864G00TR

Core
Z8
Data Bus Width
8 bit
Maximum Clock Frequency
8 MHz
Program Memory Size
64 KB
Data Ram Size
1 KB
Operating Supply Voltage
2 V to 3.6 V
Package / Case
SSOP-28
Mounting Style
SMD/SMT
Interface Type
UART
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Number Of Programmable I/os
5
Number Of Timers
2 x 8 bit, 1 x 16 bit
Processor Series
ZLF645
Program Memory Type
Flash
19-4572; Rev 0; 4/09
Bit Position
[7]
[6]
[5]
[4:3] 
[2] 
[1] 
[0]
Value
Read
Write
00
01
10
11
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Description
T8_Enable— Disable/enable the T8 counter. (Note: This register bit duplicates
the function of register bit 6 of the CTR3 register).
Disables the T8 counter if bit 6 of the CTR3 register is also 0.
Enables the T8 counter if bit 6 of the CTR3 register is also 0 and has no effect if
the T8 counter is already enabled by bit 6 of the CTR3 register being 1.
SINGLE-PASS/MODULO-N
MODULO-N mode. Counter reloads the initial value when terminal count is
reached.
SINGLE-PASS mode. Counter stops when the terminal count is reached.
Time_Out —This bit is set when the T8 terminal count is reached.
No counter time-out occurred.
Counter time-out occurred.
No effect.
Reset flag to 0. Software must reset this flag before using counter/timers.
T8 _Clock —Select the T8 input clock frequency.These bits are not reset upon
Stop Mode Recovery.
SCLK
SCLK ÷ 2
SCLK ÷ 4
SCLK ÷ 8
Capture_INT_Mask —Disable/enable interrupt when data is captured into either
LO8 or HI8 on a positive or negative edge detection in DEMODULATION mode.
This bit is not reset upon Stop Mode Recovery.
Disable data capture interrupt.
Enable data capture interrupt.
Counter_INT_Mask —Disable/enable T8 time-out interrupt. This bit is not reset
upon Stop Mode Recovery.
Disable time-out interrupt.
Enable time-out interrupt.
P34_Out —Select normal I/O or T8 output function for Port 3, pin 4.
P34 as port output.
T8 output on P34.
ZLF645 Series Flash MCUs
Product Specification
Counter/Timer Registers
120

Related parts for ZLF645E0H2864G00TR