MAX16048ACB+T Maxim Integrated, MAX16048ACB+T Datasheet - Page 41

no-image

MAX16048ACB+T

Manufacturer Part Number
MAX16048ACB+T
Description
Supervisory Circuits 8Ch EEPROM Prob System Manager
Manufacturer
Maxim Integrated
Series
MAX16046, MAX16048r
Datasheet

Specifications of MAX16048ACB+T

Rohs
yes
Table 23. Critical Fault Configuration and Enable Bits
System Managers with Nonvolatile Fault Registers
REGISTER/
ADDRESS
EEPROM
4Ah
4Bh
47h
48h
49h
12-Channel/8-Channel EEPROM-Programmable
BIT RANGE
[1:0]
[7:2]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
Critical Fault Log Control
00 = Failed lines and ADC conversion values save to EEPROM upon critical fault
01 = Failed line flags only saved to EEPROM upon critical fault
10 = ADC conversion values only saved to EEPROM upon critical fault
11 = No information saved upon critical fault
Not used
1 = Fault log triggered when MON1 is below its undervoltage threshold
1 = Fault log triggered when MON2 is below its undervoltage threshold
1 = Fault log triggered when MON3 is below its undervoltage threshold
1 = Fault log triggered when MON4 is below its undervoltage threshold
1 = Fault log triggered when MON5 is below its undervoltage threshold
1 = Fault log triggered when MON6 is below its undervoltage threshold
1 = Fault log triggered when MON6 is below its undervoltage threshold
1 = Fault log triggered when MON8 is below its undervoltage threshold
1 = Fault log triggered when MON9 is below its undervoltage threshold*
1 = Fault log triggered when MON10 is below its undervoltage threshold*
1 = Fault log triggered when MON11 is below its undervoltage threshold*
1 = Fault log triggered when MON12 is below its undervoltage threshold*
1 = Fault log triggered when MON1 is above its overvoltage threshold
1 = Fault log triggered when MON2 is above its overvoltage threshold
1 = Fault log triggered when MON3 is above its overvoltage threshold
1 = Fault log triggered when MON3 is above its overvoltage threshold
1 = Fault log triggered when MON5 is above its overvoltage threshold
1 = Fault log triggered when MON6 is above its overvoltage threshold
1 = Fault log triggered when MON7 is above its overvoltage threshold
1 = Fault log triggered when MON8 is above its overvoltage threshold
1 = Fault log triggered when MON9 is above its overvoltage threshold*
1 = Fault log triggered when MON10 is above its overvoltage threshold*
1 = Fault log triggered when MON11 is above its overvoltage threshold*
1 = Fault log triggered when MON12 is above its overvoltage threshold*
1 = Fault log triggered when MON1 is above/below its early earning threshold
1 = Fault log triggered when MON2 is above/below its early warning threshold
1 = Fault log triggered when MON3 is above/below its early warning threshold
1 = Fault log triggered when MON4 is above/below its early warning threshold
1 = Fault log triggered when MON5 is above/below its early warning threshold
1 = Fault log triggered when MON6 is above/below its early warning threshold
1 = Fault log triggered when MON7 is above/below its early warning threshold
1 = Fault log triggered when MON8 is above/below its early warning threshold
DESCRIPTION
41