The extended memory page contains the ADC conver-
sion result registers (see Table 3). These registers are
also used internally for fault threshold comparison.
Voltage-monitoring thresholds are compared with the 8
MSBs of the conversion results. Inputs that are not
Table 3. ADC Conversion Registers
* MAX16046 only
System Managers with Nonvolatile Fault Registers
EXTENDED PAGE
ADDRESS
0Ch
0Dh
0Ah
0Bh
0Eh
00h
01h
02h
03h
04h
05h
06h
07h
08h
09h
0Fh
10h
11h
12h
13h
14h
15h
16h
17h
12-Channel/8-Channel EEPROM-Programmable
BIT RANGE
[7:0]
[7:6]
[5:0]
[7:0]
[7:6]
[5:0]
[7:0]
[7:6]
[5:0]
[7:0]
[7:6]
[5:0]
[7:0]
[7:6]
[5:0]
[7:0]
[7:6]
[5:0]
[7:0]
[7:6]
[5:0]
[7:0]
[7:6]
[5:0]
[7:0]
[7:6]
[5:0]
[7:0]
[7:6]
[5:0]
[7:0]
[7:6]
[5:0]
[7:0]
[7:6]
[5:0]
MON1 ADC Conversion Result (MSB)
MON1 ADC Conversion Result (LSB)
Reserved
MON2 ADC Conversion Result (MSB)
MON2 ADC Conversion Result (LSB)
Reserved
MON3 ADC Conversion Result (MSB)
MON3 ADC Conversion Result (LSB)
Reserved
MON4 ADC Conversion Result (MSB)
MON4 ADC Conversion Result (LSB)
Reserved
MON5 ADC Conversion Result (MSB)
MON5 ADC Conversion Result (LSB)
Reserved
MON6 ADC Conversion Result (MSB)
MON6 ADC Conversion Result (LSB)
Reserved
MON7 ADC Conversion Result (MSB)
MON7 ADC Conversion Result (LSB)
Reserved
MON8 ADC Conversion Result (MSB)
MON8 ADC Conversion Result (LSB)
Reserved
MON9 ADC Conversion Result (MSB)*
MON9 ADC Conversion Result (LSB)*
Reserved
MON10 ADC Conversion Result (MSB)*
MON10 ADC Conversion Result (LSB)*
Reserved
MON11 ADC Conversion Result (MSB)*
MON11 ADC Conversion Result (LSB)*
Reserved
MON12 ADC Conversion Result (MSB)*
MON12 ADC Conversion Result (LSB)*
Reserved
enabled are not converted by the ADC; they contain the
last value acquired before that channel was disabled.
The ADC conversion result registers are reset to 00h at
boot-up. These registers are not reset when a reboot
command is executed.