Specifications of MAX11014BGTM+

Rohs
yes
Common Mode Rejection Ratio (min)
90 dB
Operating Supply Voltage
0.5 V to 11 V
Supply Current
2.8 mA
Maximum Power Dissipation
2162.2 mW
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
TQFN-48
Available Set Gain
13.98 dB
The software ALARM configuration register controls
which voltage and temperature channels trigger the
ALARM output and whether the ALARM comparators
operate in windowing or hysteresis mode. Set the com-
mand byte to 3Eh to write to the software ALARM config-
uration register. Set the command byte to BEh to read
the software ALARM configuration register. Bits
D15–D12 are don’t care. Set the VALARM2 bit, D11, to 1
to enable ALARM functionality for GATE2 voltage mea-
surements. Set the VWIN2 bit, D10, to 1 to monitor the
GATE2 voltage with the ALARM comparator in window-
ing mode. Set VWIN2 to 0 to monitor the GATE2 voltage
with the ALARM comparator in hysteresis mode.
Table 12a. GATE Voltage Hysteresis Levels
Table 12b. Sense Voltage/Temperature Hysteresis Levels
Table 12c. ALARM Clamp Modes
ALM_CLMP1
VGHYST1
ITHYST1
0
0
1
1
0
0
1
1
0
0
1
1
ALM_CLMP0
______________________________________________________________________________________
VGHYST0
ITHYST0
0
1
0
1
0
1
0
1
0
1
0
1
ALMSCFG (Read/Write)
Default state. The GATE_ outputs are clamped to the respective external voltage applied at
ACLAMP_ independent of alarms. GATE_ remains clamped until this register value is changed
or a software clear command is issued.
The corresponding ALARM bit in the ALARM flag register goes high if an ALARM condition is
triggered by a conversion of sense voltage, temperature, or GATE_ voltage. However, the
GATE_ outputs are not clamped.
Fully automatic clamping. The GATE_ outputs are clamped to the respective external voltage
applied at ACLAMP_ when an ALARM condition is triggered. The clamp is removed if a
subsequent temperature or sense voltage conversion removes the ALARM condition. GATE_
remains clamped when a GATE_ voltage ALARM is triggered. For a GATE_ voltage ALARM,
ALM_CLMP 10 mode functions the same as 11 mode. This exception breaks the feedback
loop created by sampling GATE_ voltage and then clamping the same signal.
Semi-automatic clamping. The GATE_ outputs are clamped to the respective external voltage
applied at ACLAMP_ when an ALARM condition is triggered. If an ALARM condition is
triggered, the ALM_CLMP bits are overwritten to 00, causing a permanent clamp condition.
Clear this permanent clamp condition with a subsequent write to reset the ALM_CLMP bits.
8 LSBs of hysteresis.
16 LSBs of hysteresis.
32 LSBs of hysteresis.
64 LSBs of hysteresis.
8 LSBs of hysteresis.
16 LSBs of hysteresis.
32 LSBs of hysteresis.
64 LSBs of hysteresis.
Automatic RF MESFET Amplifier
Drain-Current Controllers
Set the TALARM2 bit, D9, to 1 to enable ALARM func-
tionality for channel 2 temperature measurements. Set
the TWIN2 bit, D8, to 1 to monitor the channel 2 tem-
perature with the ALARM comparator in windowing
mode. Set TWIN2 to 0 to monitor the channel 2 temper-
ature with the ALARM comparator in hysteresis mode.
Set the IALARM2 bit, D7, to 1 to enable ALARM func-
tionality for channel 2 sense voltage (RCS2+ to RCS2-)
measurements. Set the IWIN2 bit, D6, to 1 to monitor
the channel 2 sense voltage with the ALARM compara-
tor in windowing mode. Set IWIN2 to 0 to monitor the
channel 2 sense voltage with the ALARM comparator in
hysteresis mode.