1893BKLFT IDT, 1893BKLFT Datasheet - Page 70

no-image

1893BKLFT

Manufacturer Part Number
1893BKLFT
Description
Ethernet ICs 3.3V 10/100 BASE TX INTEGRATED PHYCEIVER
Manufacturer
IDT
Datasheet

Specifications of 1893BKLFT

Rohs
yes
Part # Aliases
ICS1893BKLFT
7.8 Register 6: Auto-Negotiation Expansion Register
7.8.1 IEEE Reserved Bits (bits 6.15:5)
ICS1893BF, Rev. F, 5/13/10
Table 7-13
Auto-Negotiation process.
Note:
Table 7-13. Auto-Negotiation Expansion Register (register 6 [0x06])
† As per the IEEE Std 802.3u, during any write operation to any bit in this register, the STA must write the default value
The ISO/IEC specification reserves these bits for future use. When an STA:
ICS uses some reserved bits to invoke auxiliary functions. To ensure proper operation of the ICS1893BF,
an STA must maintain the default value of these bits. Therefore, IDT recommends that an STA always write
the default value of any reserved bits during all management register write operations.
Reserved bits 5.15:5 are Command Override Write (CW) bits. When the Command Register Override bit
(bit 16.15) is logic:
6.15
6.14
6.13
6.12
6.11
6.10
6.9
6.8
6.7
6.6
6.5
6.4
6.3
6.2
6.1
6.0
Bit
to all Reserved bits.
Reads a reserved bit, the ICS1893BF returns a logic zero.
Writes to a reserved bit, the STA must use the default value specified in this data sheet.
Zero, the ICS1893BF isolates all STA writes to CW bits.
One, an STA can modify the value of these bits
ICS1893BF Data Sheet - Release
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
Parallel detection fault
Link partner Next Page
able
Next Page able
Page received
Link partner
Auto-Negotiation able
For an explanation of acronyms used in
lists the bits for the Auto-Negotiation Expansion Register, which indicates the status of the
Definition
Always 0
Always 0
Always 0
Always 0
Always 0
Always 0
Always 0
Always 0
Always 0
Always 0
Always 0
No Fault
Link partner is not Next
Page able
Local device is not Next
Page able
Next Page not received
Link partner is not
Auto-Negotiation able
When Bit = 0
Copyright © 2009, IDT, Inc.
All rights reserved.
70
Table
7-13, see
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Multiple technologies
detected
Link partner is Next Page
able
Local device is Next Page
able
Next Page received
Link partner is
Auto-Negotiation able
When Bit = 1
Chapter 1, “Abbreviations and
Chapter 7 Management Register Set
cess
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
Ac-
RO
RO
RO
RO
RO
SF
LH
LH
Acronyms”.
fault
De-
0†
0†
0†
0†
0†
0†
0†
0†
0†
0†
0†
0
May, 2010
0
0
1
0
Hex
0
0
0
4

Related parts for 1893BKLFT