1893BKLFT IDT, 1893BKLFT Datasheet - Page 58

no-image

1893BKLFT

Manufacturer Part Number
1893BKLFT
Description
Ethernet ICs 3.3V 10/100 BASE TX INTEGRATED PHYCEIVER
Manufacturer
IDT
Datasheet

Specifications of 1893BKLFT

Rohs
yes
Part # Aliases
ICS1893BKLFT
7.3.2 100Base-TX Full Duplex (bit 1.14)
7.3.3 100Base-TX Half Duplex (bit 1.13)
7.3.4 10Base-T Full Duplex (bit 1.12)
7.3.5 10Base-T Half Duplex (bit 1.11)
ICS1893BF, Rev. F, 5/13/10
The STA reads this bit to learn if the ICS1893BF can support 100Base-TX, full-duplex operations. The
ISO/IEC specification requires that the ICS1893BF must set bit 1.14 to logic:
Bit 1.14 is a Command Override Write bit, which allows an STA to alter the default value of this bit. [See the
description of bit 16.15, the Command Override Write Enable bit, in
Control
The STA reads this bit to learn if the ICS1893BF can support 100Base-TX, half-duplex operations. The
ISO/IEC specification requires that the ICS1893BF must set bit 1.13 to logic:
This bit 1.13 is a Command Override Write bit, which allows an STA to alter the default value of this bit.
[See the description of bit 16.15, the Command Override Write Enable bit, in
Extended Control
The STA reads this bit to learn if the ICS1893BF can support 10Base-T, full-duplex operations. The
ISO/IEC specification requires that the ICS1893BF must set bit 1.12 to logic:
This bit 1.12 is a Command Override Write bit, which allows an STA to alter the default value of this bit.
[See the description of bit 16.15, the Command Override Write Enable bit, in
Extended Control
The STA reads this bit to learn if the ICS1893BF can support 10Base-T, half-duplex operations. The
ISO/IEC specification requires that the ICS1893BF must set bit 1.11 to logic:
Bit 1.11 of the ICS1893BF Status Register is a Command Override Write bit., which allows an STA to alter
the default value of this bit. [See the description of bit 16.15, the Command Override Write Enable bit, in
Section 7.11, “Register 16: Extended Control
Zero if it cannot support 100Base-TX, full-duplex operations.
One if it can support 100Base-TX, full-duplex operations. (For the ICS1893BF, the default value of bit
1.14 is logic one, in that the ICS1893BF supports 100Base-TX, full-duplex operations.)
Zero if it cannot support 100Base-TX, half-duplex operations.
One if it can support 100Base-TX, half-duplex operations. (For the ICS1893BF, the default value of bit
1.13 is logic one. Therefore, when an STA reads the Status Register, the STA is informed that the
ICS1893BF supports 100Base-TX, half-duplex operations.)
Zero if it cannot support 10Base-T, full-duplex operations.
One if it can support 10Base-T, full-duplex operations. (For the ICS1893BF, the default value of bit 1.12
is logic one. Therefore, when an STA reads the Status Register, the STA is informed that the ICS1893BF
supports 10Base-T, full-duplex operations.)
Zero if it cannot support 10Base-T, half-duplex operations.
One if it can support 10Base-T, half-duplex operations. (For the ICS1893BF, the default value of bit 1.11
is logic one. Therefore, when an STA reads the Status Register, the STA is informed that the ICS1893BF
supports 10Base-T, half-duplex operations.)
ICS1893BF Data Sheet - Release
Register”.]
Register”.]
Register”.]
Copyright © 2009, IDT, Inc.
All rights reserved.
Register”.]
58
Section 7.11, “Register 16: Extended
Chapter 7 Management Register Set
Section 7.11, “Register 16:
Section 7.11, “Register 16:
May, 2010

Related parts for 1893BKLFT