1894K-40LFT IDT, 1894K-40LFT Datasheet - Page 47

no-image

1894K-40LFT

Manufacturer Part Number
1894K-40LFT
Description
Ethernet ICs 3.3V 10/100 PHY RMII
Manufacturer
IDT
Datasheet

Specifications of 1894K-40LFT

Rohs
yes
Part # Aliases
ICS1894K-40LFT
10Base-T: Heartbeat Timing (SQE)
10Base-T Heartbeat (SQE) Timing Diagram
IDT® 10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE
ICS1894-40
10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE
The table below lists the significant time periods for the 10Base-T heartbeat (that is, the Signal Quality Error). The
time periods consist of timings of signals on the following pins:
The 10Base-T Heartbeat (SQE) Timing Diagram shows the timing diagram for the time periods.
Note:
1. For more information on 10Base-T SQE operations, see the section “10Base-T Operation: SQE Test”.
2. In 10Base-T mode, one bit time = 100 ns.
TXEN
TXCLK
COL
Period
Time
TXEN
TXCLK
COL
t1
t2
COL Heartbeat Assertion Delay from
TXEN De-Assertion
COL Heartbeat Assertion Duration
Parameter
t1
10Base-T Half Duplex
10Base-T Half Duplex
Conditions
t2
47
Min.
Typ.
1000
850
ICS1894-40
Max. Units
1500
1500
PHYCEIVER
ns
ns
REV K 022412