KPC8544EVTANG Freescale Semiconductor, KPC8544EVTANG Datasheet - Page 41

no-image

KPC8544EVTANG

Manufacturer Part Number
KPC8544EVTANG
Description
Microprocessors - MPU PQ38K 8544E
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of KPC8544EVTANG

Product Category
Microprocessors - MPU
Rohs
yes
Maximum Clock Frequency
800 MHz
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Package / Case
FCPBGA
I/o Voltage
1.8 V, 2.5 V, 3.3 V
Minimum Operating Temperature
0 C
Factory Pack Quantity
5
8.7.5.2
Table 39
Figure 24
Figure 25
Freescale Semiconductor
At recommended operating conditions with L/TV
REF_CLK clock period
REF_CLK duty cycle
REF_CLK peak-to-peak jitter
Rise time REF_CLK (20%–80%)
Fall time REF_CLK (80%–20%)
RXD[1:0], CRS_DV, RX_ER setup time to
REF_CLK rising edge
RXD[1:0], CRS_DV, RX_ER hold time to REF_CLK
rising edge
Note:
1. The symbols used for timing specifications follow the pattern of t
inputs and t
timing (MR) with respect to the time data input signals (D) reach the valid state (V) relative to the t
going to the high (H) state or setup time. Also, t
signals (D) went invalid (X) relative to the t
the clock reference symbol representation is based on three letters representing the clock of a particular functional. For
example, the subscript of t
with the appropriate letter: R (rise) or F (fall).
shows the RMII receive AC timing specifications.
provides the AC test load for eTSEC.
shows the RMII receive AC timing diagram.
(first two letters of functional block)(reference)(state)(signal)(state)
Parameter/Condition
RMII Receive AC Timing Specifications
REF_CLK
RXD[1:0]
CRS_DV
MPC8544E PowerQUICC III Integrated Processor Hardware Specifications, Rev. 6
RX_ER
Output
MRX
represents the MII (M) receive (RX) clock. For rise and fall times, the latter convention is used
Table 39. RMII Receive AC Timing Specifications
Figure 25. RMII Receive AC Timing Diagram
t
RMRH
t
RMRDV
DD
MRX
Figure 24. eTSEC AC Test Load
of 3.3 V ± 5%.or 2.5 V ± 5%.
t
RMR
clock reference (K) going to the low (L) state or hold time. Note that, in general,
MRDXKL
Z
0
= 50 Ω
Symbol
t
t
t
t
RMRDX
t
RMRDV
t
RMRH
RMRR
symbolizes MII receive timing (GR) with respect to the time data input
t
RMRF
RMRJ
Valid Data
RMR
1
t
RMRF
(first two letters of functional block)(signal)(state)(reference)(state)
for outputs. For example, t
Enhanced Three-Speed Ethernet (eTSEC), MII Management
15.0
Min
1.0
1.0
4.0
2.0
35
R
L
t
RMRDX
t
= 50 Ω
RMRR
20.0
Typ
50
LV
DD
MRDVKH
/2
Max
25.0
250
2.0
2.0
65
MRX
symbolizes MII receive
clock reference (K)
Unit
ns
ps
ns
ns
ns
ns
%
Notes
for
41

Related parts for KPC8544EVTANG