HFCT-5964ATG NEL [Nel Frequency Controls,inc], HFCT-5964ATG Datasheet - Page 10

no-image

HFCT-5964ATG

Manufacturer Part Number
HFCT-5964ATG
Description
ATG Single Mode Laser Small Form Factor Transceivers for ATM, SONET OC-3 /SDH STM-1 Part of the Agilent METRAK family
Manufacturer
NEL [Nel Frequency Controls,inc]
Datasheet
Package and Handling Instructions
Flammability
The HFCT-5964TL/TG/NL/NG/
ATL/ATG transceiver housing
consists of high strength, heat
resistant and UL 94 V-0 flame
retardant plastic and metal
packaging.
Recommended Solder and Wash
Process
The HFCT-5964TL/TG/NL/NG/
ATL/ATG are compatible with
industry-standard wave solder
processes.
Process plug
This transceiver is supplied with
a process plug for protection of
the optical port within the LC
connector receptacle. This
process plug prevents
contamination during wave
solder and aqueous rinse as well
as during handling, shipping and
storage. It is made of a high-
temperature, molded sealing
material that can withstand +85
°C, and a rinse pressure of 110
lbs per square inch.
The process plug should only be
used once. After removing it
from the transceiver, it must not
be used again as a process plug;
however, if it has not been
contaminated, it can be reused
as a dust cover.
Recommended Solder fluxes
Solder fluxes used with the
HFCT-5964TL/TG/NL/NG/ATL/
ATG should be water-soluble,
organic fluxes. Recommended
solder fluxes include Lonco
3355-11 from London Chemical
West, Inc. of Burbank, CA, and
100 Flux from Alpha-Metals of
Jersey City, NJ.
Recommended Cleaning/Degreasing
Chemicals
Alcohols: methyl, isopropyl,
isobutyl.
Aliphatics: hexane, heptane
Other: naphtha.
10
Do not use partially halogenated
hydrocarbons such as 1,1.1
trichloroethane, ketones such as
MEK, acetone, chloroform, ethyl
acetate, methylene dichloride,
phenol, methylene chloride, or
N-methylpyrolldone. Also,
Agilent does not recommend the
use of cleaners that use
halogenated hydrocarbons
because of their potential
environmental harm.
LC SFF Cleaning Recommendations
In the event of contamination of
the optical ports, the
recommended cleaning process
is the use of forced nitrogen. If
contamination is thought to have
remained, the optical ports can
be cleaned using a NTT
international Cletop stick type
(diam. 1.25 mm) and HFE7100
cleaning fluid.
Figure 8. Recommended Panel Mounting
(0.4 ±0.004)
DIMENSIONS IN MILLIMETERS (INCHES)
1.
2.
10.16 ±0.1
FIGURE DESCRIBES THE RECOMMENDED FRONT PANEL OPENING FOR A LC OR SG SFF TRANSCEIVER.
SFF TRANSCEIVER PLACED AT 15.24 mm (0.6) MIN. SPACING.
14.22 ±0.1
±0.004)
(0.56
DETAIL A
15.24
(0.6)
TOP OF PCB
15.24
(0.6)
B
(0.039)
(0.62 MAX. 0.59 MIN.)
15.75 MAX. 15.0 MIN.
1
A
SECTION B - B
SOLDER POSTS
B

Related parts for HFCT-5964ATG