SX1210 SEMTECH [Semtech Corporation], SX1210 Datasheet - Page 34

no-image

SX1210

Manufacturer Part Number
SX1210
Description
Ultra-Low Power Integrated UHF Receiver
Manufacturer
SEMTECH [Semtech Corporation]
Datasheet
When the programmed Sync word is detected the user can assume that this incoming packet is for the node and
can be processed accordingly.
The packet handler is the block used in Packet mode. Its functionality is fully described in section 5.5.
The control block configures and controls the full chip’s behavior according to the settings programmed in the
configuration registers.
Rev 2– Sept 8
ADVANCED COMMUNICATIONS & SENSING
Size: Sync word size can be set to 8, 16, 24 or 32 bits via RXParam_Sync_size.
Error tolerance: The number of errors tolerated in the Sync word recognition can be set to 0, 1, 2 or 3 via
RXParam_Sync_tol.
Value: The Sync word value is configured in SYNCParam_Sync_value.
5.2.4. Packet Handler
5.2.5. Control
th
, 2008
5.2.3.2. Configuration
Page 34 of 73
www.semtech.com
SX1210

Related parts for SX1210