LC-X1228P Panasonic - BSG, LC-X1228P Datasheet - Page 9

BATT SEALED LEAD ACID 12V 28AH

LC-X1228P

Manufacturer Part Number
LC-X1228P
Description
BATT SEALED LEAD ACID 12V 28AH
Manufacturer
Panasonic - BSG
Series
LCr
Datasheet

Specifications of LC-X1228P

Voltage - Rated
12V
Capacity
28Ah
Size / Dimension
6.47" L x 4.92" W x 6.89" H (165mm x 125mm x 175mm)
Termination Style
Nut/Bolt, M5
Rechargeability
Yes
Weight
25 lbs (11.3kg)
For Use With
BVW122250003N - BATTERY CHG UNIV 12VDC @ 2.25A271-2390 - BATTERY CHG UNIV 12VDC @ 2.25A271-2386 - BATTERY CHG UNIV 12VDC @ 1.2A271-2385 - BATTERY CHG UNIV 12VDC @ 600MA271-2382 - BATTERY CHG UNIV 12VDC @ 500MA271-2381 - BATTERY CHG UNIV 12VDC @ 500MA271-2380 - BATTERY CHG 120VAC 12VDC @ 500MA271-2378 - BATTERY CHG 120VAC 12VDC @ 300MAPATC-08 - BATT CHARGER 12V 1.5A X 2 UNITPATC-03 - BATTERY CHARGER 12 VOLT 1.5 AMP
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
LC-X1228
LC-XB1228
LC-XB1228P
LCX1228P
P049
PRECAUTIONS FOR HANDLING VALVE-REGULATED LEAD-ACID BATTERIES-
RECOMMENDATION
(1) The recommended cut-off voltage during
(2) Avoid overdischarge, and charge the battery
(3) If a charge method and a charge condition other
discharge depends on the size of the discharge
current. The relationship between the storage
battery discharge current and the ideal discharge
cut-off voltage is described in Panasonic
specifications and technical handbooks.
the voltage drops below the recommended
discharge cut-off voltage.
the recommended discharge cut-off voltage is
recharged, the storage battery may generate heat
which could deform it or cause condensation to
form on the battery casing due to the evaporation
of moisture from inside the battery. Discharging
below the recommended discharge cut-off
voltage may also accelerate the deterioration of
the battery’s performance characteristics.
immediately after discharge. The instruction
manual of the equipment should contain informa-
tion telling the user not to overdischarge the
battery and to charge the battery immediately
after the use of the equipment (discharge). Even
if discharge of the battery is stopped before
voltage decreases to such a level that the battery-
driven equipment stops being operational, dete-
rioration of the battery may be accelerated by the
so-called sulphation phenomenon if it is not
recharged after use. The low voltage cut-off
circuit should be designed so that it can com-
pletely cut off the discharge current including a
weak current.
than that described in the specification and the
technical brochures is to be adopted, charge/
discharge characteristics and life characteristics
of the battery should be thoroughly checked in
advance. The adoption of adequate charge
methods and adequate charge conditions are
crucial to ensure safe use of the battery and for
fully utilizing the battery capacity.
Do not continue discharging to the point where
If a storage battery that was discharged below
VRLA BATTERIES PAGE 8
(4) For the cycle operation of the battery (application
(5) Avoid parallel charging of batteries in cycle use,
(6) During trickle or float charge of the battery,
(7) Make sure to turn off the switch of the battery
(8) When the equipment is not used for a long period,
of the battery as the main source of power by
repeating charge and discharge), use a charger
which operates by controlling either the charge
period or charge quantity. Continue charging the
battery for the time specified or until the charge
completion lamp, if provided, indicates completion
of charge. If charging is suspended before
completion, the service life of the battery may be
shortened.
as this may shorten the service life of the batter-
ies by causing an imbalance in charge/discharge
state among the batteries connected in parallel.
measure the total voltage with a high-accuracy
voltmeter of Class 0.5 or better. If the voltage
readout does not meet the specified value,
investigate the reason and take proper measures.
A total voltage that is lower than the specified
value indicates insufficient charge which may
reduce the battery capacity; a voltage higher than
specified indicates an overcharge which may
shorten service life of the battery or cause
problems such as thermal runaway in some
cases.
equipment after use, otherwise excessive
discharge may cause deterioration in battery
performance and shorten service life.
remove the battery from the equipment, charge it
fully, and store it in a place where humidity is low.
Unsatisfactory storage conditions may cause
deterioration in battery performance, shorten
service life and could cause rust to form on the
terminals.
AUGUST 2003