BATT SEALED LEAD ACID 12V 28AH

LC-X1228P

Manufacturer Part Number
LC-X1228P
Description
BATT SEALED LEAD ACID 12V 28AH
Manufacturer
Panasonic - BSG
Series
LCr
Datasheet

Specifications of LC-X1228P

Voltage - Rated
12V
Capacity
28Ah
Size / Dimension
6.47" L x 4.92" W x 6.89" H (165mm x 125mm x 175mm)
Termination Style
Nut/Bolt, M5
Rechargeability
Yes
Weight
25 lbs (11.3kg)
For Use With
BVW122250003N - BATTERY CHG UNIV 12VDC @ 2.25A271-2390 - BATTERY CHG UNIV 12VDC @ 2.25A271-2386 - BATTERY CHG UNIV 12VDC @ 1.2A271-2385 - BATTERY CHG UNIV 12VDC @ 600MA271-2382 - BATTERY CHG UNIV 12VDC @ 500MA271-2381 - BATTERY CHG UNIV 12VDC @ 500MA271-2380 - BATTERY CHG 120VAC 12VDC @ 500MA271-2378 - BATTERY CHG 120VAC 12VDC @ 300MAPATC-08 - BATT CHARGER 12V 1.5A X 2 UNITPATC-03 - BATTERY CHARGER 12 VOLT 1.5 AMP
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
LC-X1228
LC-XB1228
LC-XB1228P
LCX1228P
P049
PRECAUTIONS FOR HANDLING VALVE-REGULATED LEAD-ACID BATTERIES-
6. Maintenance and checking
WARNING
(1) Clean the battery with a slightly damp cloth,
(2) Replace the battery with a new one within the
7. Emergency measures
WARNING
(1) The battery contains diluted sulfuric acid, a very
ensure there is no excess water on the cloth by
squeezing it well. Do not use a dry cloth or a
duster, as it may cause the battery to generate
static electricity, leading to possible ignition and
bursting of the battery.
time period specified in the instruction manual or
equipment.
should be replaced when its capacity has
decreased to 50% of the initial capacity (at an
ambient temperature of 77°F (25°C) or below).
In the trickle or float application of the battery
(application as stand-by power) at an ambient
temperature higher than 77°F (25°C), the period
for which the battery can be used before
replacement is shortened by a half for every
10°C rise of temperature. When the discharge
current becomes higher than 0.25 CA, the run
time and battery life is also shortened.
toxic substance. If the battery leaks and the
liquid inside spills on the skin or clothing,
immediately wash it off with plenty of clean
water. If the liquid splashes into eyes,
immediately flush the eyes with plenty of clean
water and consult a doctor. Sulfuric acid in the
eyes may cause loss of eyesight and acid on
the skin will cause burns.
Follow the guideline which states the battery
VRLA BATTERIES PAGE 9
CAUTION
(1) Do not apply organic solvents such as paint thinner,
RECOMMENDATION
(1) Keep the terminals of the battery clean. Dirty
CAUTION
(1) If any corrosion of the terminals, leakage or
shortened near the end of its service life (when
discharge time has decreased to 50% of the initial).
This is also the period when battery problems such
as internal short, dry-up of electrolyte (increase in
internal resistance) and corrosion of the cathode
grids will occur. Replace the battery before these
conditions are reached: if the battery continues to
be used under these conditions, maximum dis-
charge current will continue flowing, which may
lead to thermal runaway or leakage.
gasoline, kerosene and benzene or liquid deter-
gents to the battery. If these are brought into con-
tact with the battery case, it may crack, causing
leakage.
terminals may cause inadequate contact of the
battery to the equipment body, leading to power
failure or charge failure.
deformation of the case of the battery is found, do
not use the battery and turn off the power supply. If
a battery which is irregular or substandard in any
way continues to be used, leakage, fire or bursting
of the battery may occur and there is also a
potential for electric shock.
The usable period for the battery is markedly