LC-X1228P Panasonic - BSG, LC-X1228P Datasheet - Page 4

BATT SEALED LEAD ACID 12V 28AH

LC-X1228P

Manufacturer Part Number
LC-X1228P
Description
BATT SEALED LEAD ACID 12V 28AH
Manufacturer
Panasonic - BSG
Series
LCr
Datasheet

Specifications of LC-X1228P

Voltage - Rated
12V
Capacity
28Ah
Size / Dimension
6.47" L x 4.92" W x 6.89" H (165mm x 125mm x 175mm)
Termination Style
Nut/Bolt, M5
Rechargeability
Yes
Weight
25 lbs (11.3kg)
For Use With
BVW122250003N - BATTERY CHG UNIV 12VDC @ 2.25A271-2390 - BATTERY CHG UNIV 12VDC @ 2.25A271-2386 - BATTERY CHG UNIV 12VDC @ 1.2A271-2385 - BATTERY CHG UNIV 12VDC @ 600MA271-2382 - BATTERY CHG UNIV 12VDC @ 500MA271-2381 - BATTERY CHG UNIV 12VDC @ 500MA271-2380 - BATTERY CHG 120VAC 12VDC @ 500MA271-2378 - BATTERY CHG 120VAC 12VDC @ 300MAPATC-08 - BATT CHARGER 12V 1.5A X 2 UNITPATC-03 - BATTERY CHARGER 12 VOLT 1.5 AMP
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
LC-X1228
LC-XB1228
LC-XB1228P
LCX1228P
P049
PRECAUTIONS FOR HANDLING VALVE-REGULATED LEAD-ACID BATTERIES
Safety Precautions
1. Environment and condition of use
DANGER
(1) Do not load valve-regulated lead-acid batteries
WARNING
(1) Charge the battery using a specified charger or
(2) When using the battery in medical equipment*,
(3) Avoid direct contact of the battery with metallic
(4) Do not place the battery near a device that may
(5) Avoid placing the battery near a heat-generating
* The battery should only be used in non life critical medical equipment.
When any medical equipment incorporating a Panasonic VRLA battery
is planned, please notify Panasonic.
(hereinafter described as “the battery”) in airtight
equipment. Use of the battery in airtight equipment
may cause explosion of the equipment or injury.
under the charging condition specified by
Panasonic. Charging the battery under any other
conditions may cause the battery to overheat,
emit hydrogen gas, leak, ignite, or burst.
provide a back-up system other than the main
battery. Failure of the main battery in the absence
of a back-up power could lead to injury.
containers; acid- and heat-resistant insulators
should be employed. Leakage of the battery in the
absence of insulators may cause problems such
as release of fumes and ignition.
cause sparks (such as a switch or a fuse). The
battery may generate flammable gas when
charged, so remember to keep the battery away
from fire oran open flame to prevent any sparks
from igniting or causing explosions.
part (such as a transformer). Using the battery
near a heat source may cause the battery to
overheat, leak, ignite, or burst.
VRLA BATTERIES PAGE 3
CAUTION
(1) The operating temperature range for the battery is
(3) Do not place or store the battery in an automobile
(4) Use of the battery in a dusty environment is not
(2) Do not allow the battery to be immersed in or
specified below. Use of the battery at
temperatures beyond this range may cause
battery damage.
Normal operating temperature of the battery is
77°F (25°C).
When discharged (equipment in use): 5°F to
122°F (-15°C to 50°C)
When charged: 32°F to 104°F (0°C to 40°C)
During storage: 5°F to 104°F (-15°C to 40°C)
wetted with water/sea-water; as it may corrode
the battery, ignite or create an electric shock
hazard.
in hot weather, under direct sunlight, in front of a
stove, or near fire. Use or storage of the battery in
these places may cause battery leakage, fire or
bursting.
recommended, as it may cause the battery to
short. The battery should be periodically checked
when used in such an environment.
AUGUST 2003
-CONT.