LC-X1228P Panasonic - BSG, LC-X1228P Datasheet - Page 6

BATT SEALED LEAD ACID 12V 28AH

LC-X1228P

Manufacturer Part Number
LC-X1228P
Description
BATT SEALED LEAD ACID 12V 28AH
Manufacturer
Panasonic - BSG
Series
LCr
Datasheet

Specifications of LC-X1228P

Voltage - Rated
12V
Capacity
28Ah
Size / Dimension
6.47" L x 4.92" W x 6.89" H (165mm x 125mm x 175mm)
Termination Style
Nut/Bolt, M5
Rechargeability
Yes
Weight
25 lbs (11.3kg)
For Use With
BVW122250003N - BATTERY CHG UNIV 12VDC @ 2.25A271-2390 - BATTERY CHG UNIV 12VDC @ 2.25A271-2386 - BATTERY CHG UNIV 12VDC @ 1.2A271-2385 - BATTERY CHG UNIV 12VDC @ 600MA271-2382 - BATTERY CHG UNIV 12VDC @ 500MA271-2381 - BATTERY CHG UNIV 12VDC @ 500MA271-2380 - BATTERY CHG 120VAC 12VDC @ 500MA271-2378 - BATTERY CHG 120VAC 12VDC @ 300MAPATC-08 - BATT CHARGER 12V 1.5A X 2 UNITPATC-03 - BATTERY CHARGER 12 VOLT 1.5 AMP
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
LC-X1228
LC-XB1228
LC-XB1228P
LCX1228P
P049
PRECAUTIONS FOR HANDLING VALVE-REGULATED LEAD-ACID BATTERIES-
(3) Do not carry the battery by hanging it from the
(4) When carrying the battery, exercise caution not to
(5) Do not underestimate the weight of the battery. As
(6) Do not bring covered wires containing plasticizer
(7) Do not cover the battery with a material which
(8) In fastening bolts and nuts of the battery, observe
1.197(5)
0.236(6)
0.315(8)
Diameter
M5
M6
M8
terminal or the lead wire, as it may cause damage
to the battery.
apply a strong shock to it by dropping it, jarring it
or causing it to collide with other objects, as this
may cause damage to the battery.
it is heavy for its volume, careless handling of the
battery may cause backache or other injuries to
the operator.
or non- rigid PVC sheets in contact with the
battery. Do not apply organic solvents such as
paint thinner, gasoline, kerosene and benzene or
liquid detergents to the battery. When brought in
contact with these materials, the battery case
may crack, causing leakage of the battery.
generates static electricity, such as a PVC sheet.
A static charge may trigger fire or explosion
the torque values specified: otherwise, sparks
may be generated and damage of the terminal
may occur. The fastening torque of bolts and nuts
is as follows:
(Vertical position)
Bolt (nut) size (mm)
(1.25)
0.031
0.039
0.049
Pitch
(0.8)
(1.0)
0.591 ± 0.039
0.7870.039
0.7870.039
(15 ± 1)
(20 ± 1)
(20 ± 1)
Length
(Horizontal position)
2.0 ~ 2.9
3.9 ~ 5.4
7.8 ~ 9.8
Nm
VRLA BATTERIES PAGE 5
Fastening Torque
80 ~ 100
20 ~ 30
40 ~ 55
kg. cm.
17.3 ~ 26.0
34.6 ~ 47.6
69.3 ~ 86.6
lb. In.
(9) Apply insulation covers to terminals, joint parts,
(10) When intending to use the battery in vibrating
(11) Fasten the batteries firmly to the equipment to
RECOMMENDATION
(1) The battery and/or equipment should be installed
by skilled personnel (specialists) such as personnel
qualified for maintaining battery equipment. Handling
of the battery by unskilled personnel may lead to
dangerous errors.
bolts and nuts of the battery in order to prevent
electric shocks to personnel.
equipment such as motor cycles, engine driven
bicycles and engine driven grass shears, please
consult Panasonic in advance.
avoid the influence of vibration and/or physical
shock.
AUGUST 2003
CONT.

Related parts for LC-X1228P