X4003 Xicor, X4003 Datasheet - Page 7

no-image

X4003

Manufacturer Part Number
X4003
Description
CPU Supervisor
Manufacturer
Xicor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
X4003
Manufacturer:
XILINX
0
X4003/X4005
Figure 5. Valid Data Changes on the SDA Bus
Serial Start Condition
All commands are preceded by the start condition,
which is a HIGH to LOW transition of SDA when SCL is
HIGH. The device continuously monitors the SDA and
SCL lines for the start condition and will not respond to
any command until this condition has been met. See
Figure 6.
Figure 6. Valid Start and Stop Conditions
Serial Acknowledge
Acknowledge is a software convention used to indicate
successful data transfer. The transmitting device, either
master or slave, will release the bus after transmitting
eight bits. During the ninth clock cycle, the receiver will
pull the SDA line LOW to acknowledge that it received
the eight bits of data. Refer to Figure 7.
REV 1.1.3 4/30/02
SDA
SCL
SCL
SDA
Data Stable
Start
www.xicor.com
Data Change
Serial Stop Condition
All communications must be terminated by a stop condi-
tion, which is a LOW to HIGH transition of SDA when
SCL is HIGH. The stop condition is also used to place
the device into the Standby power mode after a read
sequence. A stop condition can only be issued after the
transmitting device has released the bus. See Figure 6.
The device will respond with an acknowledge after rec-
ognition of a start condition and the correct contents of
the slave address byte. Acknowledge bits are also pro-
vided by the X4003/4005 after correct reception of the
control register address byte, after receiving the byte
written to the control register and after the second
slave address in a read question (See Figure 8 and
See Figure 9.)
Data Stable
Stop
Characteristics subject to change without notice.
7 of 18

Related parts for X4003