X9511ZP Xicor, X9511ZP Datasheet
X9511ZP
Available stocks
Related parts for X9511ZP
X9511ZP Summary of contents
Page 1
... REV 1.1.1 2/7/02 X9511 ™ ) Potentiometer (Push Button Controlled) DESCRIPTION The Xicor X9511 is a push button controlled potentiom- eter that is ideal for push button controlled resistance trimming. The X9511 is a resistor array composed of 31 resistive elements. Between each element and at either end are tap points accessible to the wiper element ...
Page 2
... For the first second the device will be in the slow scan mode. Then if the button is held for longer than 1 second the device will go into the fast scan mode. As soon as the button is released the X9511 will return to a standby condition. www.xicor.com Description /R High Terminal H ...
Page 3
... R with V TOTAL The end to end resistance of the array will fluctuate while once V is removed Figure 2. Typical circuit with ASE store pin used in AUTOSTORE mode www.xicor.com Removed CC 3.3µ ASE V L Characteristics subject to change without notice. ...
Page 4
... Unlimited wiper adjustment....... (Non-Store operation) Wiper position store operations.......................100,000 Physical Characteristics Marking Includes Manufacturer’s Trademark Resistance Value or Code Date Code (2) (2) /31. TOT W(n+1) www.xicor.com data changes (expected)) = ±1 Ml (actual)–V w(n) w(n) – Ml] = +0.2 Ml w(n) Characteristics subject to change without notice ...
Page 5
... –1 0.8 40 100 –5 +5 – Wiper Increments 10KW 323Ω Parameter and the voltage applied to the potentiometer pins during power-up CC ramp rate spec is always in effect. CC www.xicor.com Limits 5V ±10% Unit Test Conditions held at V the other µ µ Ω Max. Wiper Current ±1mA ...
Page 6
... This parameter is periodically sampled and not 100% tested. Slow Mode Timing PU V Note: ( the A.C. timing diagram refers to the minimum incremental change in the wiper voltage. REV 1.1.1 2/7/ Autos Cycle in Progress t ASTO Store Time Time (ms GAP W www.xicor.com V ASTH V ASEND (1) MI Characteristics subject to change without notice ...
Page 7
... X9511 Fast Mode Timing Note: ( the A.C. timing diagram refers to the minimum incremental change in the wiper voltage. REV 1.1.1 2/7/ FAST t S SLOW ( Second www.xicor.com Characteristics subject to change without notice. ...
Page 8
... Ref. Seating Plane 0.150 (3.81) 0.125 (3.18) 0.110 (2.79) 0.090 (2.29) 0.325 (8.25) 0.300 (7.62) Max. www.xicor.com 0.260 (6.60) 0.240 (6.10) 0.060 (1.52) 0.020 (0.51) 0.145 (3.68) 0.128 (3.25) 0.025 (0.64) 0.015 (0.38) 0.065 (1.65) 0.045 (1.14) 0.020 (0.51) 0.016 (0.41) 0° ...
Page 9
... REV 1.1.1 2/7/02 Pin 1 0.014 (0.35) 0.019 (0.49) 0.188 (4.78) 0.197 (5.00) (4X) 7° 0.050 (1.27) X 45° 0.0075 (0.19) 0.010 (0.25) FOOTPRINT www.xicor.com 0.150 (3.80) 0.228 (5.80) 0.158 (4.00) 0.244 (6.20) 0.053 (1.35) 0.069 (1.75) 0.004 (0.19) 0.010 (0.25) 0.050"Typical 0.050" Typical 0.250" ...
Page 10
... Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and prices at any time and without notice. Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, or licenses are implied. TRADEMARK DISCLAIMER: Xicor and the Xicor logo are registered trademarks of Xicor, Inc ...