ST72T311 ST Microelectronics, ST72T311 Datasheet - Page 63

no-image

ST72T311

Manufacturer Part Number
ST72T311
Description
8-BIT MCU WITH 8 TO 16K OTP/EPROM
Manufacturer
ST Microelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST72T311BN9T6
Manufacturer:
ST
Quantity:
1 778
Part Number:
ST72T311BN9T6
Manufacturer:
ST
0
Part Number:
ST72T311J2B6
Manufacturer:
ST
Quantity:
648
Part Number:
ST72T311J2B6
Manufacturer:
ST
0
Part Number:
ST72T311J2T6
Manufacturer:
ST
0
Part Number:
ST72T311J4
Manufacturer:
ST
Quantity:
5
Part Number:
ST72T311J4136
Manufacturer:
ST
0
Part Number:
ST72T311J4B6
Manufacturer:
ST
0
Part Number:
ST72T311J4B6S
Manufacturer:
ST
Quantity:
191
Part Number:
ST72T311N4B6
Manufacturer:
ST
Quantity:
20 000
Part Number:
ST72T311N4B6S
Manufacturer:
AD
Quantity:
540
SERIAL COMMUNICATIONS INTERFACE (Cont’d)
EXTENDED RECEIVE PRESCALER DIVISION
REGISTER (ERPR)
Read/Write
Reset Value: 0000 0000 (00h)
Allows setting of the Extended Prescaler rate divi-
sion factor for the receive circuit.
Bit 7:1 = ERPR[7:0] 8-bit Extended Receive Pres-
caler Register.
The extended Baud Rate Generator is activated
when a value different from 00h is stored in this
register. Therefore the clock frequency issued
from the 16 divider (see Figure 36) is divided by
the binary factor set in the ERPR register (in the
range 1 to 255).
The extended baud rate generator is not used af-
ter a reset.
Table 17. SCI Register Map and Reset Values
ERPR
Address
7
7
(Hex.)
50
51
52
53
54
55
57
ERPR
6
ERPR
SR
Reset Value
DR
Reset Value
BRR
Reset Value
CR1
Reset Value
CR2
Reset Value
ERPR
Reset Value
ETPR
Reset Value
5
Register
Name
ERPR
4
ERPR
3
ERPR7
ETPR7
TDRE
SCP1
DR7
TIE
R8
7
1
0
0
0
0
-
-
ERPR
2
ERPR6
ETPR6
ERPR
SCP0
TCIE
DR6
1
TC
T8
6
1
0
0
0
0
-
-
ERPR
0
0
ERPR5
ETPR5
RDRF
SCT2
DR5
RIE
5
0
0
0
0
x
-
-
EXTENDED TRANSMIT PRESCALER DIVISION
REGISTER (ETPR)
Read/Write
Reset Value:0000 0000 (00h)
Allows setting of the External Prescaler rate divi-
sion factor for the transmit circuit.
Bit 7:1 = ETPR[7:0] 8-bit Extended Transmit Pres-
caler Register.
The extended Baud Rate Generator is activated
when a value different from 00h is stored in this
register. Therefore the clock frequency issued
from the 16 divider (see Figure 36) is divided by
the binary factor set in the ETPR register (in the
range 1 to 255).
The extended baud rate generator is not used af-
ter a reset.
ETPR
7
7
ERPR4
ETPR4
SCT1
IDLE
DR4
ILIE
M
4
0
0
0
0
x
-
-
ETPR
6
ERPR3
ETPR3
WAKE
ETPR
SCT0
DR3
OR
TE
5
3
0
0
0
0
x
-
-
ETPR
4
ERPR2
ETPR2
SCR2
DR2
RE
NF
0
0
ST72E311 ST72T311
2
0
x
0
-
-
ETPR
3
ETPR
ERPR1
ETPR1
SCR1
RWU
DR1
2
FE
1
0
x
0
0
0
-
-
ETPR
1
63
ERPR0
ETPR0
SCR0
DR0
SBK
63/100
0
0
0
0
0
ETPR
x
-
-
-
0
0

Related parts for ST72T311