ST62P08C ST Microelectronics, ST62P08C Datasheet - Page 78

no-image

ST62P08C

Manufacturer Part Number
ST62P08C
Description
(ST62P08C - ST62P20C) 8-BIT MCU
Manufacturer
ST Microelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST62P08C/MBU
Manufacturer:
ST
0
Part Number:
ST62P08C/MHH
Manufacturer:
ST
0
Part Number:
ST62P08C6
Manufacturer:
ST
0
Part Number:
ST62P08CM6/MBU
Manufacturer:
ST
0
Part Number:
ST62P08CM6/RCE
Manufacturer:
ST
0
ST6208C/ST6209C/ST6210C/ST6220C
EMC CHARACTERISTICS (Cont’d)
11.7.2 Absolute Electrical Sensitivity
Based on three different tests (ESD, LU and DLU)
using specific measurement methods, the product
is stressed in order to determine its performance in
terms of electrical sensitivity. For more details, re-
fer to the AN1181 application note.
11.7.2.1 Electro-Static Discharge (ESD)
Electro-Static Discharges (3 positive then 3 nega-
tive pulses separated by 1 second) are applied to
the pins of each sample according to each pin
combination. The sample size depends of the
number of supply pins of the device (3 parts*(n+1)
supply pin). Two models are usually simulated:
Human Body Model and Machine Model. This test
conforms to the JESD22-A114A/A115A standard.
See Figure 57 and the following test sequences.
Human Body Model Test Sequence
– C
Absolute Maximum Ratings
Notes:
1. Data based on characterization results, not tested in production.
Figure 57. Typical Equivalent ESD Circuits
78/105
1
ator.
HIGH VOLTAGE
V
V
GENERATOR
Symbol
ESD(HBM)
L
ESD(MM)
is loaded through S1 by the HV pulse gener-
PULSE
Electro-static discharge voltage
(Human Body Model)
Electro-static discharge voltage
(Machine Model)
S1
C
L
100pF
HUMAN BODY MODEL
Ratings
R=1500
ST6
T
T
A
A
S2
+25 C
+25 C
– S1 switches position from generator to R.
– A discharge from C
– S2 must be closed 10 to 100ms after the pulse
Machine Model Test Sequence
– C
– S1 switches position from generator to ST6.
– A discharge from C
– S2 must be closed 10 to 100ms after the pulse
– R (machine resistance), in series with S2, en-
to the ST6 occurs.
delivery period to ensure the ST6 is not left in
charge state. S2 must be opened at least 10ms
prior to the delivery of the next pulse.
ator.
delivery period to ensure the ST6 is not left in
charge state. S2 must be opened at least 10ms
prior to the delivery of the next pulse.
sures a slow discharge of the ST6.
HIGH VOLTAGE
GENERAT OR
L
is loaded through S1 by the HV pulse gener-
Conditions
PULSE
L
S1
L
through R (body resistance)
to the ST6 occurs.
C
L
200pF
Maximum value
MACHINE MODEL
2000
ST6
200
1)
Unit
V
S2

Related parts for ST62P08C