HCPL-316 ETC, HCPL-316 Datasheet - Page 6

no-image

HCPL-316

Manufacturer Part Number
HCPL-316
Description
2.0 Amp Gate Drive Optocoupler with Integrated (VCE) Desaturation Detection and Fault Status Feedback
Manufacturer
ETC
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-316J
Manufacturer:
AVAGO
Quantity:
20 700
Part Number:
HCPL-316J
Manufacturer:
AD
Quantity:
1 939
Part Number:
HCPL-316J
Manufacturer:
AGILENT
Quantity:
20 000
Part Number:
HCPL-316J#500
Manufacturer:
AGILENT
Quantity:
3 169
Part Number:
HCPL-316J#500
Manufacturer:
AGILENT
Quantity:
20 000
Part Number:
HCPL-316J-000E
Manufacturer:
KOITECH
Quantity:
713
Part Number:
HCPL-316J-000E
Manufacturer:
AVAGO
Quantity:
21 000
Part Number:
HCPL-316J-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
HCPL-316J-500E
Manufacturer:
ST
0
Part Number:
HCPL-316J-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
HCPL-316J-500E
0
Company:
Part Number:
HCPL-316J-500E
Quantity:
6 000
Company:
Part Number:
HCPL-316J-500E
Quantity:
3 400
Part Number:
HCPL-316J-500E/HCPL316J-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Regulatory Information
The HCPL-316J is pending
approval by the following
organizations:
VDE
Approved under VDE0884/06.92
with V
VDE 0884 Insulation Characteristics*
* Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application. Surface mount classification is class A in accordance with CECCOO802.
** Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations
section, (VDE 0884) for a detailed description of Method a and Method b partial discharge test profiles.
Figure 2. Dependence of Safety Limiting Values on Temperature.
1400
1200
1000
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b**
Input to Output Test Voltage, Method a**
Highest Allowable Overvoltage**
Safety-limiting values - maximum values allowed in the event of
a failure, also see Figure 2.
Insulation Resistance at T
800
600
400
200
0
V
Partial Discharge < 5 pC
V
Partial Discharge < 5 pC
(Transient Overvoltage t
Case Temperature
Input Power
Output Power
for rated mains voltage
for rated mains voltage
for rated mains voltage
0
IORM
IORM
IORM
T
25
S
– CASE TEMPERATURE – °C
= 891 Vpeak.
x 1.875 = V
x 1.5 = V
50
75 100
P
P
S
S
, OUTPUT
, INPUT
PR
125
, Type and Sample Test, t
PR
150 175
, 100% Production Test with t
Description
S
ini
, V
150 Vrms
300 Vrms
600 Vrms
200
= 10 sec)
IO
= 500 V
UL
Recognized under UL 1577,
component recognition program,
File E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File CA
88324.
m
= 60 sec,
m
= 1 sec,
P
P
Symbol
S, OUTPUT
S, INPUT
V
V
IORM
V
V
IOTM
R
T
PR
PR
S
S
6
Characteristic
55/100/21
>10
1670
1336
6000
1200
I - IV
I - III
I - II
891
175
400
2
9
V
V
V
V
Unit
mW
mW
PEAK
PEAK
PEAK
PEAK
C