THERMAL SHUTDOWN 
Temperature sensing is provided inside IR3895. The trip 
threshold is typically set to 145
exceeded, thermal shutdown turns off both MOSFETs and 
resets the internal soft start. 
Automatic restart is initiated when the sensed 
temperature drops within the operating range. There is  
a 20
EXTERNAL SYNCHRONIZATION 
IR3895 incorporates an internal phase lock loop (PLL) 
circuit which enables synchronization of the internal 
oscillator to an external clock. This function is important to 
avoid sub‐harmonic oscillations due to beat frequency for 
embedded systems when multiple point‐of‐load (POL) 
regulators are used. A multi‐function pin, Rt/Sync, is used 
to connect the external clock. If the external clock is 
present before the converter turns on, Rt/Sync pin can be 
connected to the external clock signal solely and no other 
resistor is needed. If the external clock is applied after the 
converter turns on, or the converter switching frequency 
needs to toggle between the external clock frequency and 
the internal free‐running frequency, an external resistor 
from Rt/Sync pin to Gnd is required to set the free‐running 
frequency.  
When an external clock is applied to Rt/Sync pin after the 
converter runs in steady state with its free‐running 
I
OCP
LIMIT
OCP
= DC current limit hiccup point 
= Current limit Valley Point 
o
C hysteresis in the thermal shutdown threshold. 
I
LIMIT
20
2
Figure 8: Timing Diagram for  
I
AUGUST 08, 2012    | DATA SHEET|    Rev 3.1
Current Limit Hiccup  
(2)
 
o
C. When trip threshold is 
Single‐Input Voltage, Synchronous Buck Regulator  
- 20 -P
 
16A Highly Integrated SupIRBuck  
frequency, a transition from the free‐running frequency to 
the external clock frequency will happen. This transition is 
to gradually make the actual switching frequency equal to 
the external clock frequency, no matter which one is 
higher. On the contrary, when the external clock signal is 
removed from Rt/Sync pin, the switching frequency is also 
changed to free‐running gradually. In order to minimize 
the impact from these transitions to output voltage, a 
diode is recommended to add between the external clock 
and Rt/Sync pin, as shown in Fig9a. Figure 9b shows the 
timing diagram of these transitions. 
An internal circuit is used to change the PWM ramp slope 
according to the clock frequency applied on Rt/Sync pin. 
Even though the frequency of the external synchronization 
clock can vary in a wide range, the PLL circuit will make 
sure that the ramp amplitude is kept constant, requiring no 
adjustment of the loop compensation. Vin variation also 
affects the ramp amplitude, which will be discussed 
separately in Feed‐Forward section. 
Figure 9a: Configuration of External Synchronization
Figure 9: Timing Diagram for Synchronization  
to the external clock (Fs1>Fs2 or Fs1<Fs2)
Rt/Sync
IR3895
Gnd
IR3895 
PD‐97746
  