ADP5061 AD [Analog Devices], ADP5061 Datasheet - Page 31

no-image

ADP5061

Manufacturer Part Number
ADP5061
Description
Tiny I2C Programmable Linear Battery Charger
Manufacturer
AD [Analog Devices]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADP5061ACBZ-4-R7
Manufacturer:
Freescale
Quantity:
1 051
Part Number:
ADP5061ACBZ-5-R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Data Sheet
Bit No.
2
1
0
Table 26. Functional Settings 2, Register Address 0x08
Bit No.
7
6
5
[4:3]
[2:0]
Table 27. Interrupt Enable Register, Register Address 0x09
Bit No.
7
6
5
4
3
2
1
0
Bit Name
EN_EOC
Not used
EN_CHG
Bit Name
EN_JEITA
JEITA_SELECT
EN_CHG_VLIM
IDEAL_DIODE[1:0]
VSYSTEM[2:0]
Mnemonic
Not used
EN_THERM_LIM_INT
EN_WD_INT
EN_TSD_INT
EN_THR_INT
EN_BAT_INT
EN_CHG_INT
EN_VIN_INT
Access
R/W
R/W
R/W
R/W
R/W
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Access
R/W
R/W
Default
1
0
Default
0 = JEITA disabled
0 = JEITA1
0
00
000 = 4.3 V
Default
0
0
0
0
0
0
0
Rev. 0 | Page 31 of 44
Description
0 = end of charge not allowed.
1 = end of charge allowed.
0 = battery charging is disabled.
1 = battery charging is enabled.
Description
0 = JEITA compliance of the Li-Ion temperature battery charging
specifications is disabled.
1 = JEITA compliance enabled.
0 = JEITA1 is selected.
1 = JEITA2 is selected.
0 = charging voltage limit disabled.
1 = voltage limit activated. The charger prevents charging until the
battery voltage drops below the V
00 = ideal diode operates always when V
01 = ideal diode operates when V
10 = ideal diode is disabled.
11 = ideal diode is disabled.
System voltage programming bus. The values of the system voltage
can be programmed to the following values:
000 = 4.3 V.
001 = 4.4 V.
010 = 4.5 V.
011 = 4.6 V.
100 = 4.7 V.
101 = 4.8 V.
110 = 4.9 V.
111 = 5.0 V.
Description
0 = isothermal charging interrupt is disabled.
1 = isothermal charging interrupt is enabled.
0 = watchdog alarm interrupt is disabled.
1 = watchdog alarm interrupt is enabled.
0 = overtemperature interrupt is disabled.
1 = overtemperature interrupt is enabled.
0 = THR temperature thresholds interrupt is disabled.
1 = THR temperature thresholds interrupt is enabled.
0 = battery voltage thresholds interrupt is disabled.
1 = battery voltage thresholds interrupt is enabled.
0 = charger mode change interrupt is disabled.
1 = charger mode change interrupt is enabled.
0 = VINx pin voltage thresholds interrupt is disabled.
1 = VINx pin voltage thresholds interrupt is enabled.
ISO_S
CHG_VLIM
< V
ISO_S
ISO_B
threshold.
< V
and V
ISO_B
BAT_SNS
.
ADP5061
> V
WEAK
.

Related parts for ADP5061