EP1K100 ETC [List of Unclassifed Manufacturers], EP1K100 Datasheet - Page 25

no-image

EP1K100

Manufacturer Part Number
EP1K100
Description
Programmable Logic Device Family
Manufacturer
ETC [List of Unclassifed Manufacturers]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1K100C208-3N
Manufacturer:
ALTERA
Quantity:
60
Part Number:
EP1K100EFI484-2
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1K100F484-2N
Manufacturer:
ALTERA
Quantity:
648
Part Number:
EP1K100FC256
Manufacturer:
LINEAR
Quantity:
423
Part Number:
EP1K100FC256
Manufacturer:
ALTERA
Quantity:
298
Part Number:
EP1K100FC256
Manufacturer:
ALTERA
Quantity:
313
Part Number:
EP1K100FC256-1
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1K100FC256-1
Manufacturer:
ALTERA
0
Company:
Part Number:
EP1K100FC256-1
Quantity:
17
Part Number:
EP1K100FC256-1N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1K100FC256-1N
Manufacturer:
ALTERA
Quantity:
10 000
Part Number:
EP1K100FC256-1N
Manufacturer:
ALTERA
0
ACEX 1K Programmable Logic Device Family Data Sheet
Asynchronous Clear
The flipflop can be cleared by either LABCTRL1 or LABCTRL2. In this mode,
the preset signal is tied to VCC to deactivate it.
Asynchronous Preset
An asynchronous preset is implemented as an asynchronous load, or with
an asynchronous clear. If DATA3 is tied to VCC, asserting LABCTRL1
asynchronously loads a one into the register. Alternatively, the Altera
software can provide preset control by using the clear and inverting the
register’s input and output. Inversion control is available for the inputs to
both LEs and IOEs. Therefore, if a register is preset by only one of the two
LABCTRL signals, the DATA3 input is not needed and can be used for one of
the LE operating modes.
Asynchronous Preset & Clear
When implementing asynchronous clear and preset, LABCTRL1 controls
the preset, and LABCTRL2 controls the clear. DATA3 is tied to VCC, so that
13
asserting LABCTRL1 asynchronously loads a one into the register,
effectively presetting the register. Asserting LABCTRL2 clears the register.
Asynchronous Load with Clear
When implementing an asynchronous load in conjunction with the clear,
LABCTRL1 implements the asynchronous load of DATA3 by controlling the
register preset and clear. LABCTRL2 implements the clear by controlling
the register clear; LABCTRL2 does not have to feed the preset circuits.
Asynchronous Load with Preset
When implementing an asynchronous load in conjunction with preset, the
Altera software provides preset control by using the clear and inverting
the input and output of the register. Asserting LABCTRL2 presets the
register, while asserting LABCTRL1 loads the register. The Altera software
inverts the signal that drives DATA3 to account for the inversion of the
register’s output.
Asynchronous Load without Preset or Clear
When implementing an asynchronous load without preset or clear,
LABCTRL1 implements the asynchronous load of DATA3 by controlling the
register preset and clear.
Altera Corporation
25

Related parts for EP1K100