afct-5805amz Avago Technologies, afct-5805amz Datasheet - Page 6

no-image

afct-5805amz

Manufacturer Part Number
afct-5805amz
Description
155 Mb/s Single Mode Fiber Optic Transceiver For Atm, Sonet Oc-3/sdh Stm-1
Manufacturer
Avago Technologies
Datasheet
Regulatory Compliance
The AFCT-5805xxxZ is intended to enable commercial
system designers to develop equipment that complies
with the various regulations governing certifi cation of
Information Technology Equipment. See the Regulatory
Compliance Table 1 for details. Additional information is
available from your Avago Technologies sales represen-
tative.
Electrostatic Discharge (ESD)
There are two design cases in which immunity to ESD
damage is important.
The fi rst case is during handling of the transceiver prior
to mounting it on the circuit board. It is important to
use normal ESD handling precautions for ESD sensitive
devices. These precautions include using grounded wrist
straps, work benches and fl oor mats in ESD controlled
areas.
The second case to consider is static discharges to the
exterior of the equipment chassis containing the trans-
ceiver parts. To the extent that the duplex SC connector
is exposed to the outside of the equipment chassis it may
be subject to whatever ESD system level test criteria that
the equipment is intended to meet.
6
Electromagnetic Interference (EMI)
Most equipment designs utilizing these high-speed
transceivers from Avago Technologies will be required
to meet the requirements of FCC in the United States,
CENELEC EN55022 (CISPR 22) in Europe and VCCI in
Japan.
The AFCT-5805xxxZ has been characterized without a
chassis enclosure to demonstrate the robustness of the
part’s integral shielding. Performance of a system con-
taining these transceivers within a well designed chassis
is expected to be better than the results of these tests
with no chassis enclosure.
Immunity
Equipment utilizing these AFCT-5805xxxZ transceivers
will be subject to radio-frequency electromagnetic fi elds
in some environments. These transceivers, with their inte-
gral shields, have been characterized without the benefi t
of a normal equipment chassis enclosure and the results
are reported below. Performance of a system contain-
ing these transceivers within a well designed chassis
is expected to be better than the results of these tests
without a chassis enclosure.

Related parts for afct-5805amz