xr16l2550im Exar Corporation, xr16l2550im Datasheet - Page 32

no-image

xr16l2550im

Manufacturer Part Number
xr16l2550im
Description
Industry Smallest Package Uart With 2.25v To 5.5v Operation
Manufacturer
Exar Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR16L2550IM
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
XR16L2550IM
Quantity:
330
Part Number:
xr16l2550im-F
Manufacturer:
LT
Quantity:
350
Part Number:
xr16l2550im-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
xr16l2550im-F
Manufacturer:
EXAR
Quantity:
8 000
Part Number:
xr16l2550im-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
xr16l2550im-F
Quantity:
874
Part Number:
xr16l2550imTR-F
Manufacturer:
Exar Corporation
Quantity:
10 000
XR16L2550
LOW VOLTAGE DUART WITH 16-BYTE FIFO
EFR[5]: Special Character Detect Enable
EFR[6]: Auto RTS Flow Control Enable
RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is
selected, an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and
RTS de-asserts to a logic 1 at the next upper trigger level. RTS# will return to a logic 0 when FIFO data falls
below the next lower trigger level. The RTS# output must be asserted (logic 0) before the auto RTS can take
effect. RTS# pin will function as a general purpose output when hardware flow control is disabled.
EFR[7]: Auto CTS Flow Control Enable
Automatic CTS Flow Control.
These registers are used as the programmable software flow control characters XOFF1, XOFF2, XON1, and
XON2. For more details, see
4.15
Logic 0 = Special Character Detect Disabled (default).
Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with
data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set
to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If
flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= ‘10’) then flow control and special character work
normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= ‘01’) then flow control works
normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character
interrupt, if enabled via IER bit-5. Special character interrupts are cleared automatically after the next
received character.
Logic 0 = Automatic RTS flow control is disabled (default).
Logic 1 = Enable Automatic RTS flow control.
Logic 0 = Automatic CTS flow control is disabled (default).
Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts to logic
1. Data transmission resumes when CTS# returns to a logic 0.
Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write