Description
Extended Line Card Interface Controller Elic
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
pef20550H
Manufacturer:
FAI
Quantity:
543
Note: RR-frames and I-frame with first data byte equal to Ax
2.2.7.5 Special Functions
Cyclical Transmission (fully transparent)
When the extended transparent mode is selected, the SACCO supports the continuous
transmission of the XFIFO-contents.
After having written 1 to 32 bytes to the XFIFO, the command XREP/XTF/XME (XREP/
XTF in DMA-mode) is executed. Consequently the SACCO repeatedly transmits the
XFIFO-data via pin TxD.
The cyclical transmission continues until the command (CMDR:XRES) is executed or
the bit XREP is reset. The inter frame timefill pattern is issued afterwards.
When resetting XREP, data transmission is stopped after the next XFIFO-cycle is
completed, the XRES-command terminates data transmission immediately.
Note: Bit MODE:CFT must be set to "0".
Continuous Transmission (DMA-mode only)
If data transfer from system memory to the SACCO is done by DMA (DMA bit in XBCH
set), the number of bytes to be transmitted is usually defined via the transmit byte count
registers XBCH, XBCL. Setting the "transmit continuously" bit (XC) in XBCH, however,
the byte count value is ignored and the DMA-interface of the SACCO will continuously
request for transmit data any time 32 bytes can be stored in the XFIFO.
This feature can be used e.g. to
• continuously transmit voice or data onto a PCM-highway
• transmit frames exceeding the byte count programmable in XBCH,
Note: If the XC-bit is reset during continuous transmission, the transmit byte count
Receive Length Check
The SACCO offers the possibility to supervise the maximum length of received frames
and to terminate data reception in case this length is exceeded.
Semiconductor Group
(clock mode 2, ext. transp. mode)
XBCL (> 4095 bytes).
processed automatically. They are not stored in RFIFO and no interrupt is issued.
becomes valid again, and the SACCO will request the amount of DMA-transfers
programmed in XBC11 … XBC0. Otherwise the continuous transmission is
stopped when a data underrun condition occurs in the XFIFO, i.e. the DMA-
controller does not transfer further data to the SACCO. In this case an abort
sequence (min. 7 '1's) followed by the inter frame timefill pattern is transmitted (no
CRC-word is appended).
75
Functional Description
H
or D0
PEB 20550
PEF 20550
H
- EF
H
01.96