mc68hc908gp32 Freescale Semiconductor, Inc, mc68hc908gp32 Datasheet - Page 204

no-image

mc68hc908gp32

Manufacturer Part Number
mc68hc908gp32
Description
M68hc08 Microcontrollers Microcontroller
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc68hc908gp32CF8
Manufacturer:
MOT
Quantity:
600
Part Number:
mc68hc908gp32CF8
Manufacturer:
MOT
Quantity:
1 000
Part Number:
mc68hc908gp32CFB
Manufacturer:
ON
Quantity:
11
Part Number:
mc68hc908gp32CFB
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc68hc908gp32CFB
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Part Number:
mc68hc908gp32CFBE
Manufacturer:
GAIA
Quantity:
5
Part Number:
mc68hc908gp32CFBR2
Manufacturer:
FREESCALE
Quantity:
69
Part Number:
mc68hc908gp32CP
Manufacturer:
ROCKWELL
Quantity:
201
Part Number:
mc68hc908gp32CP
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Timer Interface Module (TIM)
control the output are the ones written to last. TSC0 controls and monitors the buffered output compare
function, and TIM channel 1 status and control register (TSC1) is unused. While the MS0B bit is set, the
channel 1 pin, TCH1, is available as a general-purpose I/O pin.
17.4.4 Pulse Width Modulation (PWM)
By using the toggle-on-overflow feature with an output compare channel, the TIM can generate a PWM
signal. The value in the TIM counter modulo registers determines the period of the PWM signal. The
channel pin toggles when the counter reaches the value in the TIM counter modulo registers. The time
between overflows is the period of the PWM signal.
As
of the PWM signal. The time between overflow and output compare is the pulse width. Program the TIM
to clear the channel pin on output compare if the polarity of the PWM pulse is 1. Program the TIM to set
the pin if the polarity of the PWM pulse is 0.
The value in the TIM counter modulo registers and the selected prescaler output determines the
frequency of the PWM output. The frequency of an 8-bit PWM signal is variable in 256 increments. Writing
$00FF (255) to the TIM counter modulo registers produces a PWM period of 256 times the internal bus
clock period if the prescaler select value is $000. See
The value in the TIM channel registers determines the pulse width of the PWM output. The pulse width
of an 8-bit PWM signal is variable in 256 increments. Writing $0080 (128) to the TIM channel registers
produces a duty cycle of 128/256 or 50%.
204
Figure 17-3
TCHx
In buffered output compare operation, do not write new output compare
values to the currently active channel registers. User software should track
the currently active channel to prevent writing a new value to the active
channel. Writing to the active channel registers is the same as generating
unbuffered output compares.
shows, the output compare value in the TIM channel registers determines the pulse width
OVERFLOW
PULSE
WIDTH
Figure 17-3. PWM Period and Pulse Width
PERIOD
MC68HC908GP32 Data Sheet, Rev. 10
COMPARE
OUTPUT
OVERFLOW
NOTE
17.9.1 TIM Status and Control
COMPARE
OUTPUT
OVERFLOW
COMPARE
OUTPUT
Freescale Semiconductor
Register.