cs5461 Cirrus Logic, Inc., cs5461 Datasheet - Page 27

no-image

cs5461

Manufacturer Part Number
cs5461
Description
Single-phase, Bidirectional Power/energy Ic
Manufacturer
Cirrus Logic, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
cs5461A-ISZ
Manufacturer:
CIRRUS
Quantity:
114
Part Number:
cs5461A-ISZ
Manufacturer:
CIRRUS
Quantity:
20 000
Company:
Part Number:
cs5461A-ISZ
Quantity:
267
Part Number:
cs5461A-ISZR
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
cs5461AICZ
Manufacturer:
CIRRUS
Quantity:
20 000
Figure 13 also shows the external connections that
would be made to a calibrator device, such as a PC
or custom calibration board. When the metering
system is installed, the calibrator would be used to
control calibration and/or to program user-speci-
fied commands and calibration values into the EE-
PROM. The user-specified commands/data will
determine the CS5461’s exact operation, when the
auto-boot initialization sequence is running. Any of
the valid commands can be used.
5.6.2 Auto-Boot Data for EEPROM
Below is an example code set for an auto-boot se-
quence. This code is written into the EEPROM by
the user. The serial data for such a sequence is
shown below in single-byte hexidecimal notation:
DS546F2
40 00 00 61
44 7F C4 A9
46 7F B2 53
4C 00 00 14
74 00 00 04
;In Configuration Register,
turn high-pass filters on, set
K=1.
;Write value of 0x7FC4A9 to
Current Gain Register.
;Write value of 0xFFB253 to
DC Voltage Offset Register.
;Set PulseRateE Register to
0.625 Hz.
;Unmask bit #2 (“LSD” bit in
the Mask Register).
5.6.3 Which EEPROMs Can Be Used?
Several industry-standard serial EEPROMs that
will successfully run auto-boot with the CS5461
are listed below:
These types of serial EEPROMs expect a specific
8-bit command word (00000011) in order to per-
form a memory download. The CS5461 has been
hardware programmed to transmit this 8-bit com-
mand word to the EEPROM at the beginning of the
auto-boot sequence.
E8
78 00 01 40
Atmel
National Semiconductor
Xicor
;Start continuous conversions
;Write STOP bit to Control
Register, to terminate au-
to-boot
quence, and set the EOUT
pulse output to Mechanical
Counter Format.
initialization
NM25C040M8
NM25020M8
CS5461
X25040SI
AT25010
AT25020
AT25040
se-
27