s29gl01gs Meet Spansion Inc., s29gl01gs Datasheet - Page 56

no-image

s29gl01gs

Manufacturer Part Number
s29gl01gs
Description
Manufacturer
Meet Spansion Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s29gl01gs10DHI020
Manufacturer:
SPANSION
Quantity:
100
Part Number:
s29gl01gs10FHI010
Manufacturer:
CML
Quantity:
1 392
Part Number:
s29gl01gs10FHI020
Manufacturer:
CYPRESS/赛普拉斯
Quantity:
20 000
Part Number:
s29gl01gs10TFI010
Manufacturer:
SEMIKRON
Quantity:
120
Part Number:
s29gl01gs10TFI010
0
Company:
Part Number:
s29gl01gs10TFI010
Quantity:
10
Part Number:
s29gl01gs10TFI020
Manufacturer:
RENESAS
Quantity:
981
Part Number:
s29gl01gs11DHI010
0
Part Number:
s29gl01gs11DHI020
Manufacturer:
SPANSION
Quantity:
20 000
Part Number:
s29gl01gs11DHIV10
Manufacturer:
CYPRESS
Quantity:
1 600
Part Number:
s29gl01gs11DHIV10
0
Part Number:
s29gl01gs11FHB02
Manufacturer:
SPANSION
Quantity:
20 000
Part Number:
s29gl01gs11TFI01
Manufacturer:
SPANSION
Quantity:
64
Legend:
X = Don't care.
RA = Address of the memory to be read.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed.
PD = Data to be programmed at location PA.
SA = Address of the sector selected. Address bits A
WBL = Write Buffer Location. The address must be within the same Line.
WC = Word Count is the number of write buffer locations to load minus 1.
PWAx = Password address for word0 = 00h, word1 = 01h, word2 = 02h, and word3 = 03h.
PWDx = Password data word0, word1, word2, and word3.
Notes:
1. See
2. All values are in hexadecimal.
3. Except for the following, all bus cycles are write cycle: read cycle during Read, ID/CFI Read (Manufacturing ID / Device ID), Indicator Bits,
4. Data bits DQ15-DQ8 are don't care in command sequences, except for RD, PD, WC and PWD.
5. Address bits A
6. No unlock or command cycles required when reading array data.
7. The Reset command is required to return to reading array data when device is in the ID-CFI (autoselect) mode, or if DQ5 goes High
8. Command is valid when device is ready to read array data or when device is in ID-CFI (autoselect) mode.
9. The system can read and program/program suspend in non-erasing sectors, or enter the ID-CFI ASO, when in the Erase Suspend mode.
10. The Erase Resume/Program Resume command is valid only during the Erase Suspend/Program Suspend modes.
11. Issue this command sequence to return to READ mode after detecting device is in a Write-to-Buffer-Abort state. IMPORTANT: the full
12. The Exit command returns the device to reading the array.
13. The password portion can be entered or read in any order as long as the entire 64-bit password is entered or read.
14. For PWDx, only one portion of the password can be programmed per each A0 command. Portions of the password must be programmed
15. All Lock Register bits are one-time programmable. The program state = 0 and the erase state = 1. Also, both the Persistent Protection
16. If any of the Entry commands was issued, an Exit command must be issued to reset the device into read mode.
17. Protected State = 00h, Unprotected State = 01h. The sector address for DYB set, DYB clear, or PPB Program command may be any
6.2
56
Secure Silicon Region Read, SSR Lock Read, and 2nd cycle of Status Register Read .
(while the device is providing status data).
The Erase Suspend command is valid only during a sector erase operation.
command sequence is required if resetting out of ABORT.
in sequential order (PWD0 - PWD3).
Mode Lock Bit and the Password Protection Mode Lock Bit cannot be programmed at the same time or the Lock Register Bits Program
operation aborts and returns the device to read mode. Lock Register bits that are reserved for future use are undefined and may be 0’s or
1's.
location within the sector - the lower order bits of the sector address are don't care.
Command Sequence
DYB ASO Entry
DYB Set
DYB Clear
DYB Status Read
(Note 17)
Command Set Exit
(Notes 12, 16)
Reset/ASO Exit
Table 8.1, Interface States on page 63
(Note 1)
Device ID and Common Flash Interface (ID-CFI) ASO Map
(Note 17)
(Note 17)
MAX
(Note 16)
-A11 are don't cares for unlock and command cycles, unless SA or PA required. (A
The Device ID portion of the ASO (word locations 0h to 0Fh) provides manufacturer ID, device ID, Sector
Protection State, and basic feature set information for the device.
3
2
2
1
2
1
Addr
XXX
XXX
XXX
XXX
555
SA
First
for description of bus operations.
RD (0)
Data
AA
A0
A0
90
F0
Table 6.1 Command Definitions (Sheet 3 of 3)
MAX
Volatile Sector Protection Command Set Definitions
-A16 uniquely select any sector.
Addr
XXX
2AA
SA
SA
Second
D a t a
Data
GL-S MirrorBit
55
0
1
0
Addr
555
S h e e t
Third
Data
®
E0
Family
Bus Cycles (Notes 2-5)
( P r e l i m i n a r y )
Addr
Fourth
Data
MAX
is the Highest Address pin.).
S29GL_128S_01GS_00_02 March 21, 2011
Addr
Fifth
Data
Addr
Sixth
Data
Addr
Seventh
Data

Related parts for s29gl01gs